Chapter 1: About the EthernetBlaster Communications Cable

Cable Setup

EthernetBlaster Communications Cable User Guide

© June 2008

Altera Corporation

Configuring the EthernetBlaster Hardware to Use Static IP Addressing

By default, the EthernetBlaster communications cable is factory configured to use
dynamic IP addressing.

1

Depending on your connection mode, this section assumes that you have completed
the steps in

“Remote Connection via Network Using Default Factory Settings” on

page 1–4

, or

“Direct Connection to a Computer Using Default Factory Settings” on

page 1–7

.

To configure your cable to use static IP addressing and complete your remote
connection, follow the directions below:

1. Open the EthernetBlaster Status page.

2. Click the Change Settings tab and select Static IP from the Connection Type

menu. Enter the desired IP address and other appropriate data in the settings
fields. See

Figure 1–8 on page 1–10

.

1

Contact your network administrator if you do not know the settings to
complete the Change Settings page.

3. Click Apply. The EthernetBlaster communications cable automatically restarts.

When the status LED returns to a steady green state, the EthernetBlaster
communications cable has successfully restarted and can now be added to the
Quartus II software. See

“Setting Up the EthernetBlaster Hardware in the

Quartus II Software” on page 1–12

.

Figure 1–8. EthernetBlaster Change Settings Page