TROUBLE-SHOOTING

Type of Trouble

The operation stops in the middle of

massaging in the Whole Body Sensor

Automatic Course or Automatic Course

Movement of massaging rollers in upward

direction, causing operation to stop

Check points

Countermeasure

You feel discomfort during the operation of

reclining.

(Move toward to the opposite direction

temporarily, or do not move smoothly.)

This phenomenon is caused by the operation of the timer, but is not a problem.

When the massaging rollers detach from the body, the

body pressure sensor will work to stop the operation

automatically.

Begin the operation again from the start.

(See page 11)

The display of stiffness differs

from the degree of stiffness

actually felt.

Place your fingers on the sensor.

(See page 16)

The position of massaging rollers

differ between right and left.

This phenomenon is caused by the adoption of the function of alternative tapping on the right and left

sides, but is not a problem.

This operation is conducted for safety, but is not a problem.

Operation failure

Sound and sensation during operation

During use, the following sounds or sensation may be unavoidably generated because

of its structure,

but they are not problems. (They will not affect the function, etc.)

Rattling sound during tapping

Noise during UP/DOWN operation of massaging rollers

and clinking sound during massaging operation

Creaking sound caused by massaging rollers and cloth

during massaging operation.

Gear meshing sound

Wobbling foot rest

“Gee” sound when reclined

Sound of air massage

"Pusshu" sound (Change valve sound)

Hissing sound (Exhaust sound)

"Buu" sound (Sound of pump operation)

"Pako" sound (Sound when the air bag fills)

When massaging the waist, slight sounds or shock being

generated from the massaging rollers

Bouncing movement of the massaging

s when they

move from the back to the shoulder

Check that the power plug is securely plugged into

the outlet.
Check that the POWER switch is set to the ON position. With the LOCK switch set to unlock, turn on

the POWER switch. (See page 12)

Make sure that no more than one button is being

pressed at any one time.

Please press each button separately.

Push the power plug into the outlet securely.

(See page 12)

Courses other than Air Course cannot

be selected.

Check if the chair is set to the ZERO-G 2.

After adjusting the angle of back rest, select

the massaging button.

The foot rest cannot be extended.

Check if you attempt to adjust the foot rest with the

foot rest slide lever pulled.

Adjust the foot rest with the foot rest slide

lever pulled.

The foot rest cannot be stored.

Check that the foot rest is not extended.

Return the foot rest by pulling the foot rest

slide lever.

Check if your fingers are placed on the sensor.

The degree of stiffness cannot

be measured correctly.

Slightly moisten the fingers using hand cream

and place the fingers on the sensor again.

Check your skin for dryness.

The measurement result indicates the stiffness according to the body's biological reaction to the sensor

massage, so it may differ from the stiffness the user actually feels.
Massage in relaxed condition as much as possible during massage. The degree of stiffness may not be

measured correctly when the user massages immediately after taking a bath or is given stimulation other

than sensor massage, like watching TV.

If the trouble still persists even after the following proper countermeasures have been taken, stop using the massager

to avoid possible accidents. Disconnect the power plug from the outlet and consult an authorized service center.

Do not attempt to repair the equipment at home by yourself, as it is very dangerous.

WARNING

30

SPECIFICATIONS

290 W

Power consumption

30 min.

Rated time

WHOLE BODY SENSOR AUTOMATIC COURSE

Approx. 15 minutes

(Maximum of approx. 20 minutes due to stiffness detection)

AUTOMATIC COURSE

Approx. 15 minutes

MANUAL COURSE

Approx. 15 minutes

Timer

28

3

/

4

" [width]

53

1

/

8

" [depth]

48" [height]

When not reclined (with foot rest retracted)

28

3

/

4

" [width]

72

7

/

16

" [depth]

29

15

/

16

" [height]

When reclined (with foot rest set horizontally)

Dimensions

Approx. 183 lbs.

Weight

Stand, Installation screws (Three)

Accessories

Synthetic leather

Exterior cloth

One up/down pass in approx. 35 sec.

Vertical movement speed

(5 stages) Approx. 3

5"

Tapping width

(5 stages) Approx. 3

5"

Spine stretching width

Partial stretching (Long): Repetition within Approx. 8"

Partial stretching (Short): Repetition within Approx. 4"

Range of partial stretching

Approx. 31"

Vertical stroke length

No gradation or

3

/

8

"

/one press of button

Height adjustment of massaging rollers

Approx. 120

170

Reclining angle

Reclining method

Lower body massaging

(Air pressure)

33 W

Power dissipation of electric heating equipment

Back rest: Motor-driven type (Linked with foot rest)

Foot rest: Motor-driven type (Foot rest only)

Seat surface: Motor-driven type (Linked with back rest and foot rest)

(3 stages) Approx. 23

32 kPa

There is a slight difference according to the part.

(5 stages) Approx. 10

30 times/min.

Kneading frequency

(5 stages) Approx. 300

600 times/min.

Tapping frequency

Do not use the massager on other than the designated voltage.