1. SETTING THE TEST MODE

Note: Perform the test mode in the state of 3.6 V or more in the battery

voltage.

Setting method:
1. Turn the power on.
2. Press the [BACK] key for 1.5 seconds or more, the home menu

is displayed.

3. Slide the [HOLD] key to set the hold on.
4. While pressing the [OPTION] key, press the key as following

order.

[

v

]

→ [

v

]

→ [

V

]

→ [

V

]

→ [

B

]

→ [

b

]

→ [

v

]

→ [

V

]

→ [

v

]

[

V

]

→ [

B

]

→ [

u

]

5. The set reboots when the [HOLD] key is slided to set the hold

off, and the color bar is displayed in the liquid crystal display.

6. Enter the test mode when the [BACK] key is pressed in the

state of step 5.

Note: The destination setting and sound pressure regulation setting can-

not be executed by this test mode.

2. RELEASING THE TEST MODE
1. Display the major item selection screen.
2. Press the [

v

]/[

V

] key to select the “EXITTEST”, and press the

[

B

] key to select the “SURE ?”.

3. Press the [

u

] key, turn the power off and release the test

mode.

3. CONFIGURATION OF THE TEST MODE

<>

key

Major item

Major item switching:

<>/ <>

key

<#"$,>

key

Minor item

Finish

or

Result

Start

Automatic

V

<>

key

<>

key

#

C

W 7

Minor item switching:

<>/ <>

key

W 7

4. OPERATION OF THE TEST MODE
4-1. Power

liquid crystal display

MPTAPP MENU

POWER

VCHK

AUDIO

ACHK

VIDEO

DSVCHK

OTHER

CHGCHK

CLESTE

BATTCHK

DAC
BLUETOOTH
SHUTDOWN
EXITTEST

4-1-1. Power supply voltage check
This mode is used in case power supply voltage in the state where
all power supply lines are starting is checked.

Checking method:
1. Enter the test mode.
2. Press the [

v

]/[

V

] key to select the “POWER”, and press the

[

B

] key to enter the minor item.

3. Press the [

v

]/[

V

] key to select the “VCHK”.

4. Press the [

u

] key, all power supply lines are started.

liquid crystal display

POWER VCHK

START

In this state, the power supply voltage of each power supply

line can be confi rmed by measuring the voltage.

5. Press the [BACK] key, return to minor item selection screen.

4-1-2. Consumption current (audio playback) check
This mode is used in case consumption current (audio playback)
is checked in the state where “1 kHz 0 dBs L-ch/R-ch VOLUME:
15” audio signal is outputed.

Checking method:
1. Enter the test mode.
2. Press the [

v

]/[

V

] key to select the “POWER”, and press the

[

B

] key to enter the minor item.

3. Press the [

v

]/[

V

] key to select the “ACHK”.

4. Press the [

u

] key, “1 kHz 0 dBs L-ch/R-ch VOLUE: 15”

audio signal is outputed.

liquid crystal display

POWER ACHK

1kHz 0dBs L/Rch

HPOUT [ VOL: 15 ]

START

5. In this state, each time the [OPTION] key is pressed, LCD

back light on/off switch is performed.

6. Press the [BACK] key, return to minor item selection screen.

Note: Information on the test mode must correspond in enough

security. When the leakage has been revealed by any
chance, the source of information is specifi ed.