Star Trac FITNESS S-TR User Manual

Page 46

Advertising
background image

46

STAR

TRAC

S

SERIES

TREADMILLS

O

WNER

S

M

ANUAL

Item

Lowest
Value

Highest
Value

Default
Value

Meaning

UNx

UNE

UNM

UNE

Units. UNE (English) = units of pounds, miles, feet, inches

UNM (Metric) = units of kilograms, kilometers, centimeters

NOTE: Current value is shown in P

ROFILE

Window.

TIM

5

99

99

Time. Maximum time in minutes allowed for a program, excluding cooldown.

WGT

1 (lb)
1 (kg)

500 (lb)
226 (kg)

155 (lb)
70 (kg)

Default Weight (to user). Typical weight in lb (UNx = UNE) or kg (UNx =
UNM).

Lxx

N/A

N/A

LEN

Language. Display language; either LEN (English), LGE (German), LSP
(Spanish), LDU (Dutch), LPO (Portuguese), LFR (French), LIT (Italian), LSW

(Swedish) or LKA (Katakana).
NOTE: Current value is shown in P

ROFILE

Window.

LOE

OFF

ON

OFF

Lockout Enable. Enables/disables lockout function.

LOI

001

999

001

Lockout ID. Lockout override identification number.

MNS

0.3 (mi)

0.8 (k)

2.0 (mi)

3.2 (k)

0.5 (mi)

0.8 (k)

Minimum Speed. Treadmill minimum operating speed in miles or kilometers,

based on current UNx setting.

MXS

5.0 (mi)

5.0 (k)

12.5 (mi)

20.0 (k)

5.0 (mi)

5.0 (k)

Maximum Speed. Treadmill maximum operating speed in miles or kilometers,

based on current UNx setting.

ACC

25

60

25

Acceleration Time. Time in seconds to accelerate from current speed to a

specified higher speed.

DEC

20

60

20

Deceleration Time. Time in seconds to decelerate from current speed to a

specified lower speed.

AST

OFF

ON

OFF

Auto Stop Enable. Enables/disables Auto Stop function.

AFE

OFF

ON

OFF

Auto Fan Enable. Enables/disables Auto Fan function.

PAU

30

120

60

Pause duration during a program, in seconds, either 30, 45, 60, 90 or 120.

MNP

4

110

25

Minimum PWM. Pulse duty cycle to obtain the selected MN SPD. Divide MN
PWM by 512 to get % duty cycle.

HFP

50

340

197

½ Maximum PWM. Pulse duty cycle to obtain ½ maximum speed. Divide ½

MX SPD by 512 to get % duty cycle.

MXP

172

511

400

Maximum PWM. Pulse duty cycle to obtain the selected MX SPD. Divide MX
PWM by 512 to get % duty cycle.

CRV

31

125

31

Counts/Revs. Number of counts for each motor shaft revolution.

10R

220

740

356

10 Rev distance in tenths of inches. Inches of running belt travel for 10
flywheel revolutions, always measured in inches.

PD1

1

150

1

Person Detect 1. Threshold used for Auto Stop.

PD2

1

150

1

Person Detect 2. Threshold used for Auto Stop.

PD3

1

150

1

Person Detect 3. Threshold used for Auto Stop.

NST

0

255

0

No Stop Counter. Number of times No Stop Counter switch was down or

disconnected on power-up since last reset.

KYD

0

255

0

Key Down Counter. Number of times key other than 5 or 8 was down on
power-up since last reset.

SPC

0

255

0

Speed Change Counter. Number of times speed changed suddenly more than 2
mph (UNITS=English) or 2 km/hr (UNITS=Metric) since last reset.

ELS

0

255

0

Elevation Stall Counter. Number of times elevation failed to change (stalled)