Ventura mpc troubleshooting procedures – Spectra Watermakers VENTURA 150 MPC-5000 User Manual

Page 32

Advertising
background image

32

Feed pump runs constantly,
will not turn off

Manual override switch in
“on” position

Turn off manual switch on
control box

SYMPTOMS

PROBABLE CAUSE

REMEDY

Ventura MPC Troubleshooting Procedures

No lights or display, system
does not operate

- Remote display not connected

- No power to control box

- Check display cable connec-

tions at back of display and at
control box

- Check and reset main DC

supply breaker

- Check for voltage (12 or

24vDC) at control box power
input studs

- Try manual bypass switches;

if pumps run, then control or
display is defective

Feed pump runs with loud
noise

- Intake blocked
- Air in system

- Check thru-hull valve
- Check sea strainer for leaks
- Check FWF module for leaks
- Re-prime system (restart)

Pumps run intermittently,
cycling on/off

Overpressure switch opening

- Adjust or replace switch

Display activates, but pump
will not run

- loose or broken pump wire

connection

- bad pump relay
- tanks are full

- Check wiring at terminal

block inside MPC

- Test power relay, replace
- Check tanks– system cannot

be started if tanks are full.

System runs, no product
water delivered to water
tanks, GPH bar graph
shows OK, “Good” LED
activated

- diversion

valve

inoperative

wiring fault.

- disconnected or broken

product tubing

- valve plunger stuck

- Check wiring at diversion

valve and inside control box

- Check product tubing
- Disassemble and clean diver-

sion valve plunger or replace
valve (contact factory)

System runs, no product
water delivered to water
tanks, GPH bar graph
shows OK, “reject” LED
activated

- high salinity of product

water, causing system to
reject water

- salinity probe out of cali-

bration or defective, bad
cable

- chlorine damage to mem-

branes

- pressure relief valve open

- Check for low feed pressure,

close pressure relief valve

- Check for leaks at high pres-

sure hoses

- Test product water with hand-

held tester– if over 500ppm
for 1 hour, contact factory

Close Valve