STATUS INDICATORS

When the following indicators light up or blink on the operation panel or the following
alphanumeric codes appear in the display, solve the problem immediately referring
to both the table below and the relevant page.

Be sure to use only genuine SHARP parts and supplies.

Indication

Cause and remedy

Page

Drum replacement
required indicator

Steadily
lit

Replacement of drum cartridge will be needed
soon. Prepare a new cartridge.

70

Blinking

Drum cartridge must be replaced. Replace it with
a new one.

58

TD cartridge
replacement
required indicator

Steadily
lit

Replacement of TD cartridge will be needed
soon. Prepare a new cartridge.

70

Blinking

TD cartridge must be replaced. Replace it with a
new one.

57

Misfeed indicator

Blinking

A misfeed has occurred. Remove the misfed
paper referring to the description of "MISFEED
REMOVAL".

63

The lower side cover may be open. If so, close it.

66

SPF/RSPF misfeed
indicator

Blinking

An original misfeed has occurred in the SPF/
RSPF. Remove the misfed originals referring to
the description of "E: Misfeed in the SPF/RSPF".

66

Power save indicator is
steadily lit.

The unit is in the preheat mode. Press any key to
cancel the preheat mode.

54

The unit is in the auto power shut-off mode.
Press the start (

) key to cancel the auto power

shut-off mode.

54

The paper tray indicator is
blinking.

The paper tray is not installed properly. Push the
tray into the unit securely.

"CH" is blinking in the
display.

The TD cartridge is not installed. Check if the
cartridge is installed.

57

"CH" is steadily lit in the
display.

Side cover is open. Close the side cover
securely by pressing the round projections near
the side cover open button.

"P" is blinking in the display.

The paper tray or multi-bypass tray is empty, or
single bypass has been selected in the printer
function.
Load paper.

15, 17

A misfeed has occurred in the paper tray, single
bypass or multi-bypass tray. Remove the misfed
paper.

63

A letter and a number appear
alternately.

The scan head locking switch is locked. Unlock
the scan head locking switch.

9

A letter and a number appear
alternately.

The unit will not function. Turn the power switch
off, remove the power cord from the outlet, and
contact our Technical Assistance Department at
1-(630)378-3590 in the USA or 905-568-7140 in
Canada.