Connectivity Rules

When adding hubs (repeaters) to your network, please follow the
connectivity rules listed below for Ethernet, Fast Ethernet, or
Gigabit Ethernet. However, note that because switches break up
the path for connected devices into separate collision domains,
you should not include the switch or connected cabling in your
calculations for cascade length involving other devices.

1000 Mbps Gigabit Ethernet Collision Domain

Maximum 1000BASE-T Optic Cable Distance

Maximum 1000BASE-SX Fiber Optic Cable Distance

Maximum 1000BASE-LX Fiber Optic Cable Distance

Note: Although maximum cable length for 100BASE-FX fiber

depends on the duplex mode, the maximum length for
1000BASE-SX fiber is the same for both half and full
duplex.

1000BASE-T

Cat. 5, 5e 100-ohm UTP

100 m (328 ft)

RJ-45

Fiber Size

Fiber Bandwidth

Maximum Cable Length

62.5/125 micron
MMF

160 MHz/km

7-722 ft. (2-220 m)

200 MHz/km

7-902 ft. (2-275 m)

50/125 micron
MMF

400 MHz/km

7-1641 ft. (2-500 m)

500 MHz/km

7-1805 ft. (2-550 m)

1000BASE-LX Fiber Specifications

Fiber Diameter

Fiber Bandwidth

Cable Length Range

62.5/125 micron MMF 160 MHz/km

2 - 550 m (7 - 1805 ft)

50/125 micron MMF

400 MHz/km

2 - 550 m (7 - 1805 ft)

500 MHz/km

2 - 550 m (7 - 1805 ft)

9/125 micron SMF

N/A

2 m - 5 km (7 - 16,404 ft)