Applying changes to basic network settings – Sony BKMW-E3000 User Manual

Page 14

Advertising
background image

14

Preparations

The M572: TEMP FILE CREATE setting page
appears.

4

Rotate the MULTI CONTROL knob to change the
setting.

enable: You can create files even after the capacity of

the memory label is exceeded. Files to be created
after the capacity of the memory label is exceeded
are temporary files.

disable (default setting): File creation is disabled

after the capacity of the memory label is exceeded.

5

Press the F5 (SET) button.

The message “Save Complete” appears.

Applying Changes to Basic Network
Settings

After changing basic network settings, you can use M58:
M50-M52 RENEW to apply the changes without
restarting the e-VTR. Proceed as follows.

1

Do steps 1 to 3 of “Basic Network Settings” (see page
9)
to display the M5: NETWORK page of the
maintenance menu.

2

Rotate the MULTI CONTROL knob to bring the
cursor (*) to M58: M50-M52 RENEW and press the
F5 (SET) button.

The M58: M50-M52 RENEW page appears.

3

Rotate the MULTI CONTROL knob to set the setting
to ON.

4

Press the F5 (SET) button.

The message “Complete” appears.

OTHERS CONFIG

M570: REC WITHOUT TELE-F
M571: REC WITH TELE-F
M572: TEMP FILE CREATE

OTHERS CONFIG

M572: TEMP FILE CREATE

enable

Push SET button

M5 : NETWORK

M50 : IP ADDRESS
M51 : SUBNET MASK
M52 : DEFAULT GATEWAY
M55 : TAPE LEADER CONFIG
M56 : IP CONFIG
M57 : OTHERS CONFIG
M58 : M50-M52 RENEW
M59 : RESET ALL USER

M5 : NETWORK

M58 : M50-M52 RENEW

ON

Push SET Button

M5 : NETWORK

M58 : M50-M52 RENEW

ON

Complete