220v conversion, 220 vac – Southbend Swivel Mast Bandsaw sb1018 User Manual

Page 44

Advertising
background image

-42-

For Machines Mfg. Since 8/09

Model SB1018

E L E C T R I C A L

5. Close the motor junction box and secure the

cover with the provided screw.

6. Use the 18mm wrench to remove the four

hex bolts that secure the machine to the

cabinet, then with the help of another per-

son, remove the machine from the cabinet.

Carefully place the machine on its side to

gain access to the underside of the base.

7. Remove the black plastic switch cover from

behind the switch. Disconnect the two wires

from the back of the switch, then remove the

switch.

8. Install the 220V switch, then replace the two

wires removed in Step 7 in the correspond-

ing locations from which they were removed.

9. Replace the switch cover, then with the help

of another person, place the machine back

onto the cabinet and secure it with the hex

bolts removed in Step 6.

3. Use a wire nut to connect wires #2, #3, and

#5, then wrap the wires and nuts with elec-

trical tape.

4. Connect wires #1 and #6 to the upper right

terminal and wire #4 to the lower right

terminal shown in Figure 54. Tighten the

terminal screws to secure the wires.

Figure 54. Rewired for 220V.

Start

Capacitor

200MFD

125VAC

6

1

4

Start

Capacitor

200MFD

125VAC

5

2

3

6

1

4

5

2

3

Neutral

Hot

GND

Ground

Motor (Prewired 110)

Motor (Rewired for 220V)

110 VAC

5-15 Plug

(As Recommended)

OVERLOAD

RESET

OVERLOAD

RESET

1

2

3

4

GND

GND

GND

ON/OFF

SWITCH

Hot

Hot

Ground

220 VAC

6-15 Plug

(As Recommended)

1

2

3

4

GND

GND

ON/OFF

SWITCH

220V

Wiring

Tighten These

Terminal Screws

Items Needed

Qty.

220V Switch (Part No. PSB1018204) ...................1

Phillips Screwdriver #2 ........................................1

Wrench 18mm .......................................................1

Wire nut (sized for three 14 Ga. wires) ................1

Electrical Tape .......................................As needed

Wire stripper ..........................................As needed

To convert the Model SB1018 to 220V:

1. DISCONNECT BANDSAW FROM POWER!

2. Open the motor junction box, then loosen the

wire terminals indicated in Figure 53. Re-

move the wires connected to those terminals.

Figure 53. Wiring terminal locations.

Start

Capacitor

200MFD

125VAC

6

1

4

Start

Capacitor

200MFD

125VAC

5

2

3

6

1

4

5

2

3

Neutral

Hot

GND

Ground

Motor (Prewired 110)

Motor (Rewired for 220V)

110 VAC

5-15 Plug

(As Recommended)

OVERLOAD

RESET

OVERLOAD

RESET

1

2

3

4

GND

GND

GND

ON/OFF

SWITCH

Hot

Hot

Ground

220 VAC

6-15 Plug

(As Recommended)

1

2

3

4

GND

GND

ON/OFF

SWITCH

110V Wiring

Loosen These

Terminal Screws

Wiring diagrams are provided in this section

showing the Model SB1018 wired for both 110V

and 220V. Refer to these diagrams if needed

when following this procedure. Additionally,

you must purchase a 220V switch (Part

No. PSB1018204) in order to complete the

conversion.

220V Conversion

READ PAGE 41 BEFORE

DOING ANY WIRING!

Advertising