NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Millivolt Appliance Checkout

The pilot flame should be steady, not lifting

or floating. Flame should be blue in color with

traces of orange at the outer edge.

The top 3/8" (10 mm) at the pilot generator

(thermopile) and the top 1/8" minimum (tip)

of the quick drop out thermocouple should be

engulfed in the pilot flame. The flame should

project 1" (25 mm) beyond the hood at all three

ports. See Figure 11.

To light the burner, refer to the lighting instruc-

tions on Pages 19 and 20.

1. Locate adjustment rod and adjust air shutter

to the standard setting as shown in Figure

10 (adjustment rod is located in the lower

control area).

Note: Rotating the adjustment rod coun-

terclockwise decreases air and clockwise

increases air.

2. Light appliance (follow lighting procedure

on lighting label in control compartment or

see care and operation manual).

3. Allow the burner to operate for at least 15 min-

utes while observing the flame continuously

to ensure that the proper flame appearance

has been achieved (see Figures 5 and 9 on

Pages 12 and 13). If the following condi-

tions are present, adjust accordingly.

• If flame appears weak or sooty, adjust

the air shutter, incrementally, to a more

open position until the proper flame

appearance is achieved.

• If flame stays lowered blue, adjust the

air shutter, incrementally, to a more

closed position until the proper flame

appearance is achieved.

4. Leave the control knob (off/pilot/on) in the

ON position (and the optional switches, if

installed - wall switch, remote control or

wall thermostat).

5. When satisfied that the burner flame appear-

ance is normal, re-install the lower control

compartment door.

Figure 10

***Main Burner Factory Air Shutter

Opening Setting - All Models

Natural Gas

inches (mm)

Propane Gas

inches (mm)

* TWO 1/8 (3) Slots ** TWO 11/16 (17) Slots

Air Shutter

Adjusting

Rod

Air Shutter

Adjusting

Arms

Orifice

Increase Shutter

Opening In This

Direction

Decrease Shutter

Opening In This

Direction

Air Shutter

Opening

Burner

Venturi

Tube

Note - Both air shutters open and close simultaneously

when the air shutter adjusting rod is moved.

Note - Burners are omitted in this view for clarity.

Adjustment Rod Positions, viewed from above:

* Natural Gas - fully clockwise

** Propane- fully counter clockwise

***Settings are shown for each burner.

Note - Both air shutters open and close

simultaneously when the air shutter adjusting

rod is moved.

Burners are omitted in this view for clarity.

Ref. Air shutter Patent:

U.S. Pat. 5,553,603

Figure 11

Thermocouple

Thermopile

Pilot

Nozzels

MILLIVOLT PILOT ASSEMBLY

3/8" Min.

(9 mm)

Igniter Rod

Hood

Proper Pilot Flame Appearance

WARNINGS

Air shutter adjustment should

only be performed by a quali-

fied professional service

technician.

Ensure front glass panel are

in place and sealed during

adjustment.

CAUTIONS

Soot will be produced if the

air shutter is closed too much.

Any damage due to carboning

resulting from improperly

setting the air shutter is not

covered under the warranty.

The air shutter door and nearby

appliance surfaces are hot.

Exercise caution to avoid

injury while adjusting flame

appearance.

Burner Air Shutter Adjustment Procedure