Electrical block checking, Cdp-xe570 – Sony Ericsson CDP-XE570 User Manual

Page 10

Advertising
background image

10

CDP-XE570

Procedure :
1.

Connect oscilloscpe to test point TP (TE1) and TP (VC) on
BD BOARD.

2.

Turn Power switch on.

3.

Put disc (PATD-012) in to play the number five track.

4.

Press the X (Pause) button. (Becomes the 1 track jump mode)

5.

Check the level B of the oscilliscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%

E-F Balance Check

Procedure :
1.

Connect the test point TP1 (ADJ) on DISPLAY BOARD to
the ground with a lead wire on main board.

2.

Connect oscilloscpe to test point TP (TE1) and TP (VC) on
BD BOARD.

3.

Turn the Power switch on to set the ADJ mode.

4.

Put disc (PATD-012) in to play the number five track.

5.

Press the [TIME/TEXT] button. (The tracking servo are turned
OFF.)

6.

Check the level B of the oscilliscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%

Traverse waveform

oscilloscope

BD board

TP (TE1)
TP (VC)

0V

level : 1.15

±

0.5 Vp-p

A (DC voltage)

Center of the waveform

B

0V

C (DC
voltage)

Tracking servo

OFF

Tracking servo
ON

SECTION 5

ELECTRICAL BLOCK CHECKING

Note:
1.

CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.

2.

Use PATD-012 disc (3-702-101-01) unless otherwise indicated.

3.

Use an oscilloscope with more than 10M

impedance.

4.

Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.

VOLT/DIV : 200mV
TIME/DIV : 500ns

level : 1.35

±

0.4 Vp-p

oscilloscope

BD board

TP (TE1)
TP (VC)

0V

level : 1.15

±

0.5Vp-p

A (DC voltage)

Center of the waveform

B

symmetry

RF Level Check

oscilloscope

BD board

TP (RF AC)
TP (VC)

Procedure :
1.

Connect oscilloscope to test point TP (RF AC) and TP (VC) on
BD BOARD.

2.

Connect the test point TP1 (ADJ) on DISPLAY BOARD to the
ground with a lead wire.

3.

Turn Power switch on.

4.

Put disc (PATD-012) in to play the number five track.

5.

Press the [CLEAR] buton and select the RFCK function.

6.

Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.

Note:
A clear RF signal waveform means that the shape “

” can be clearly

distinguished at the center of the waveform.

RF signal waveform

E-F Balance (1 Track Jump) Check

1 track jump waveform

7.

Press the [TIME/TEXT] button. (The tracking servo are turned
ON.) Confirm the C (DC voltage) is almost equal to the A (DC
voltage) is step 6.

Traverse waveform

8.

Disconnect the lead wire of TP1 (ADJ) connected in step 1.