Tips & tricks, settings

33

appendix.fm5

16.4.99

Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1

PC - PC direct cable connection problems: examples

Other modem drivers installed continue to operate at the same

COM port (special ISDN TA drivers, CAPI modem drivers or sim-

ilar software are often the cause of the problem).

Once successfully put into service, you can start up the direct

cable connection at both PCs. Remember that one PC must be

set as host and the other as guest. Access to files should also

be released via the settings Network/File and Print Sharing. Fi-

nally, the subfolders to be accessed by the guest must be re-

leased via the Explorer.

MAC and other operating systems

In general, Gigaset M101 Data can be implemented at every

RS232/V.24 interface if data transfer is performed transparently

and not on a company-specific basis (exception: AVM and

Eumex) or with AT Hayes commands.

However, both Gigaset M101 Data units must first be config-

ured and registered at a Windows 95/98/NT system. When pro-

gramming a modem connection, ensure that the Gigaset M101

Data unit is connected to the correct device. To do this, we rec-

ommend that you place a sticker, e.g. marked modem or PC, un-

der the Gigaset M101 Data unit so that the correct device is con-

nected later.

Meaning of "lokale Station" and "Partnerstation"

These designations are used for assigning names and indicating

stations in data traffic. "Local station" refers to the station that

undertakes all configuration operations (also for the "Partnersta-

tion"). This means that in the case of a direct cable connection,

Gigaset M101 Data setup does not have to be installed on the

second PC.

Meaning of "Basis" and "Teilnehmer"

This is an assignment in DECT radio engineering (FP = fixed

part, PP=portable part) and only applies to the air interface.

"Base" is a Gigaset telephone base station. In this case, "Teilne-

hmer" refers to a mobile unit. This is defined, for example,

through the registration option. Only one Gigaset M101 Data

"Teilnehmer" can be registered at a Gigaset M101 Data "Basis".

Meaning of local, remote

When "local" is set, the Gigaset M101 Data connected behaves

like a modem/device and performs the PC COM port function.

When "remote" is set, the Gigaset M101 Data connected be-

haves like a PC and performs the function of the connected de-

vice.