Appendix h—jitter attenuation and loop bw, Table 74. jitter values, Si53xx-rm – Silicon Laboratories SI5375 User Manual

Page 157

Advertising
background image

Si53xx-RM

Rev. 1.2

157

A

PPENDIX

H—J

ITTER

A

TTENUATION

AND

L

OOP

BW

The following illustrates the effects of different loop BW values on the jitter attenuation of the Any-Frequency
devices. The jitter consists of sine wave modulation at varying frequencies. The RMS jitter values of the modulated
sine wave input is compared to the output jitter of an Si5326 and an Si5324. For reference, the top entry in the
table lists the jitter without any modulation. For each entry in the table, the corresponding phase noise plots are
presented.

Table 74. Jitter Values

Fmod

Fdev

Jitter Start

RF Gen

Si5326

Si5324

0

0

500 Hz

1.18 ps

283 fs

281 fs

50 Hz

50 Hz

10 Hz

181 ps

169 ps

10.6 ps

100 Hz

100 Hz

50 Hz

177 ps

136 ps

2.04 ps

500 Hz

500 Hz

100 Hz

175 ps

18.6 ps

295 fs

1 kHz

1 kHz

500 Hz

184 ps

4.28 ps

292 fs

5 kHz

5 kHz

500 Hz

138 ps

297 fs

302 fs

10 kHz

10 kHz

500 Hz

139 ps

302 fs

304 fs

Notes:

1. All phase noise plots are with 622.08 MHz input and 622.08 MHz output.

Si5326 bandwidth = 120 Hz; Si5324 bandwidth = 7 Hz.

2. FM modulation at F = Fmod with modulation amplitude = Fdev.
3. Jitter start is the start of the brick wall integration band. All integration bands end at 50 MHz.
4. Phase noise measured by Agilent model E5052B.
5. RF Generator was Rohde and Schwarz model SML03.

Advertising