Connection with rs-485 – Samsung SHR-3010 User Manual

Page 13

Advertising
background image

GB

2-6

GB

2-5

DIGITAL VIDEO RECORDER

Connection with RS-485

Remote control is allowed through connection with RS-485 (up to 1.2km).

A. Communication method

Data transmission method: Start-Stop Synchronized Serial Interface

Protocol: 8 bit Data, 1 Stop bit, None Parity

Transmission speed: 4800, 9600, 19200, 38400 bpss

B. RS-485 terminal and Pin specifications

C. Data Format (Samsung Protocol)

DATA +
DATA -

9 Byte Fixed

( ) : Byte numbers

Start Code (A0H)

(1)

Data Byte

Type

Contents

Remarks

Byte 1

Start Code

0xA0

Start of Data Packet

Byte 2

Sender Addr.

Transmission Address

Source Range (0x00 ~ 0xFF)

Byte 3

Target Addr.

Reception Address

Destination Range (0x00 ~ 0xFF)

Byte 4

Only Image Recorder Command

0x0A

Byte 5

Key Function

Range (0x01 ~ 0xFF)

Byte 6

Command

0xFF

0xFF

Byte 7

0xFF

0xFF

Byte 8

0xFF

0xFF

Byte 9

Check Sum Lower byte of (0xFFFF - (values adding Byte 2 ~ Byte 8))

Start Addr.

(1)

Target Addr.

(1)

Command

(5)

Check Sum

(1)

D. Code value by key

Function

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6, 7, 8

Byte 9

Response

(Byte 5)

[SET COMMAND]

MENU

0xA0

Src.Addr

Dest.Addr.

0x0A

0x01

0xFF

Check Sum

0x01

SEARCH

0xA0

Src.Addr

Dest.Addr.

0x0A

0x02

0xFF

Check Sum

0x02

SET/STILL

0xA0

Src.Addr

Dest.Addr.

0x0A

0x03

0xFF

Check Sum

0x03

UP

0xA0

Src.Addr

Dest.Addr.

0x0A

0x04

0xFF

Check Sum

0x04

DOWN

0xA0

Src.Addr

Dest.Addr.

0x0A

0x05

0xFF

Check Sum

0x05

LEFT

0xA0

Src.Addr

Dest.Addr.

0x0A

0x06

0xFF

Check Sum

0x06

RIGHT

0xA0

Src.Addr

Dest.Addr.

0x0A

0x07

0xFF

Check Sum

0x07

PLAY

0xA0

Src.Addr

Dest.Addr.

0x0A

0x08

0xFF

Check Sum

0x08

STOP

0xA0

Src.Addr

Dest.Addr.

0x0A

0x09

0xFF

Check Sum

0x09

RECORD

0xA0

Src.Addr

Dest.Addr.

0x0A

0x0A

0xFF

Check Sum

0x0A

REC LOCK

0xA0

Src.Addr

Dest.Addr.

0x0A

0x0B

0xFF

Check Sum

0x0B

F.Shuttle 1

0xA0

Src.Addr

Dest.Addr.

0x0A

0x0C

0xFF

Check Sum

0x0C

F.Shuttle 2

0xA0

Src.Addr

Dest.Addr.

0x0A

0x0D

0xFF

Check Sum

0x0D

F.Shuttle 3

0xA0

Src.Addr

Dest.Addr.

0x0A

0x0E

0xFF

Check Sum

0x0E

F.Shuttle 4

0xA0

Src.Addr

Dest.Addr.

0x0A

0x0F

0xFF

Check Sum

0x0F

F.Shuttle 5

0xA0

Src.Addr

Dest.Addr.

0x0A

0x10

0xFF

Check Sum

0x10

F.Shuttle 6

0xA0

Src.Addr

Dest.Addr.

0x0A

0x11

0xFF

Check Sum

0x11

F.Shuttle 7

0xA0

Src.Addr

Dest.Addr.

0x0A

0x12

0xFF

Check Sum

0x12

F.Shuttle 8

0xA0

Src.Addr

Dest.Addr.

0x0A

0x13

0xFF

Check Sum

0x13

R.Shuttle 1

0xA0

Src.Addr

Dest.Addr.

0x0A

0x14

0xFF

Check Sum

0x14

R.Shuttle 2

0xA0

Src.Addr

Dest.Addr.

0x0A

0x15

0xFF

Check Sum

0x15

R.Shuttle 3

0xA0

Src.Addr

Dest.Addr.

0x0A

0x16

0xFF

Check Sum

0x16

R.Shuttle 4

0xA0

Src.Addr

Dest.Addr.

0x0A

0x17

0xFF

Check Sum

0x17

R.Shuttle 5

0xA0

Src.Addr

Dest.Addr.

0x0A

0x18

0xFF

Check Sum

0x18

R.Shuttle 6

0xA0

Src.Addr

Dest.Addr.

0x0A

0x19

0xFF

Check Sum

0x19

R.Shuttle 7

0xA0

Src.Addr

Dest.Addr.

0x0A

0x1A

0xFF

Check Sum

0x1A

R.Shuttle 8

0xA0

Src.Addr

Dest.Addr.

0x0A

0x1B

0xFF

Check Sum

0x1B

R.JOG

0xA0

Src.Addr

Dest.Addr.

0x0A

0x1C

0xFF

Check Sum

0x1C

F.JOG

0xA0

Src.Addr

Dest.Addr.

0x0A

0x1D

0xFF

Check Sum

0x1D

E. Others

Above data format and transmission speed may be changed depending on future
development conditions.

PC operates as Master, and Target Set as Slave in transmission/reception of data.

No status other than Set Key Function should be received. Provided, however, that con
tents recorded in a set should be always received for alarm function
(Some delay can be happen due to communication speed).

Advertising