DIGITAL VIDEO RECORDER

Rear View

1

2

3

4

5

No Name

Function

EXTERNAL I/O

PORT

FAN

AC IN

POWER

ALARM IN: In the N.C. (Normally Closed) mode, the system
recognizes an alarm when a High (5V) signal is input for over
0.5 seconds. In the N.O. (Normally Open) mode, the system
recognizes an alarm when a Low (0V) signal is input for over
0.5 seconds. (Please refer to “

ALARM DETECT TYPE”

on p. 3-18.)

ALARM RESET: The alarm mode is cleared when a Low (0V)
signal is input for over 0.5 seconds.

ALARM OUT: A High (5V) signal is output during alarm
recording.

TRIGGER OUT: This signal is for switching the recording
output screen of the Multiplexer.

REC IN: The system begins recording when a Low (0V) signal
is input for over 0.5 seconds.

DISK END: If the DISK END MODE of the RECORD
MODE SETUP is set to STOP, a Low (0V) signal is output for
about 1 second when the HDD becomes full during recording.
(Please refer to “

DISK END MODE” on p. 3-16.)

Fan

Connects power cable.

Power On/Off button.

8

9

10

11

1

2

3

4

7

9

5

10

8

11

6

No Name

Function

RS232 PORT

RS485 PORT

VIDEO IN/OUT

AUDIO IN/OUT

LAN

MODE

SCSI

Serial Port for remote control.

Serial Port for remote control.

Composite image signal I/O terminal (BNC Style Connector).

Audio Signal Input/Output Jacks (RCA Jacks).

LAN Cable Connection Terminal.

It is the DIP switch to set System ID, Direct Communication,
Termination, etc.

1~5 : System ID.

6

: Not Use.

7

: Termination On/Off (Of all the directly connected

systems, it sets the last system as On).

8

: Not Use.

SCSI Connector for Data Backup