3 operation, 1 general, 2 processor / charging – SIGMA BENEFON TDP-52-SN3 User Manual

Page 139: 3 operation - 7

Advertising
background image

27.1.1999

8dds50gb_fm5.fm

7

Product: DDS-50(Office set) / YO0311

8.1.3 Operation

8.1.3.1 General

Power supply unit is connected to one of the connectors on the back of the unit.
Connections on these two connectors are identical to each other. Supply voltage
(VB) turns on regulator I124 which is used to generate +5 VDC supply (VCC) for pro-
cessor and other electronics. Note that the power amplifiers of the earphone signal,
I499 and I528 do not use VCC but VB instead. Once the VCC signal has risen, also
signal CADET is activated. This causes the phone to communicate with the I2C cir-
cuit and register that office kit is present.

8.1.3.2 Processor / charging

The processor I264 is National Semiconductor COPCF888. Crystal frequency used
is 8,00 MHz.

I/O pins/signals are as follows:

A/D input I3 is used to measure the voltage of the spare battery. Amplifier I277 con-
verts the input voltage level into the new range which is suitable for A/D input. Out-
put G3 is a PWM signal which is converted with R291 and C293 into analog DC
signal. This signal is used to control the output current of the power supply unit. Out-
puts D0 and D1 are used to turn on charging current for the phone and spare bat-
tery. P-channel fets Q211 and Q221 are normally in non-conducting state (gate
voltage tied to VB) and are turned on with fets Q212 and Q222 as the control signal
has been activated. In normal operation fets Q211 and Q221 are never simulta-
neously in the conducting state.

I/O SIGNALS

DIRECTION

C0

spare battery discharge switch

IN

C7

battery pack memory

IN / OUT

D0

phone charge fet control

OUT

D1

spare battery charge fet control

OUT

D2

spare battery discharge control

OUT

D3

phone detect current control

OUT

D4

phone charge indicator (red) controlOUT

D5

phone charge indicator (green) control

OUT

D6

spare battery charge indicator (red) control

OUT

D7

spare battery charge indicator (green) control

OUT

G3

power supply control

OUT

I0

charger control from phone

IN

I1

spare battery temperature

IN

I2

phone battery voltage

IN

I3

spare battery voltage

IN

I4

PWM_CHK (not used)

IN