1 general, 2 connectors, 1 connector pc/hs signals – SIGMA BENEFON TDP-52-SN3 User Manual

Page 178: 2 connector hs signals, 1 general - 17, 2 connectors - 17

Advertising
background image

27.1.1999

Xo0236e4_fm5.fm

17

Product: DB-40 (Branching Unit) / YO0236

9.2.1 General

With the branching box you can simultaneously connect several accessories, such
as an external handset and a line converter, to the car installation kit and the hand-
portable.

9.2.2 Connectors

9.2.2.1 Connector PC/HS Signals

9.2.2.2 CONNECTOR HS SIGNALS

1 and 2

V-CHARGE

Battery charging voltage 2 A in

3

+9V

Operation voltage for accessories 0.5 A in

4

TXD

Rs232 0/5V out

5

HSMIC

Ext audio from microphone 1 kHz/ 400
mVrms

6and 7

GND

Ground

8

HSERP

Ext audio for earphone 1 kHz/200 mVrms

9

RXD

Rs232 0/5 V in

10

I2CINT

I2c interruption, input to radio 0/5 V

11

SCL

I2c clock 0/5 V

12

SDA

I2c data 0/5 V

13

CHCONT

Voltage for controlling charger current
0...5 VDC analog

14

EXTIO

Extra-IO

1 and 2

V-CHARGE

Battery charging voltage 2A in

3

9V

Operation voltage for accessories 0.5 A
out

5

HSMIC

Ext audio from microphone 1 kHz / 400
mVrms

6 and 7

GND

Ground

8

HSERP

Ext audio for loudspeaker amplifier 1 kHz
/ 200 mVrms

10

I2CINT

I2c interruption, input to radio 0/5 V

11

SCL

I2c clock 0/5 V

12

SDA

I2c data 0/5 V

13

TXD

Rs232 0/5 V out

14

RXD

Rs232 0/5 V in

16

CHCGONT

Voltage for controlling charger current
0...5 VDC analog

Advertising