8 input- and output-signals, 8 input- and output-signals - 40 – SIGMA BENEFON TDP-52-SN3 User Manual

Page 74

Advertising
background image

27.1.1999

4Z0700GB.__2

40

Product: TDP-52-SN3 (Sigma Gold) / OY0725

5.3.8 Input- and Output-Signals

SENSITIVITY CHECK

RF input from the duplex filter

463,000...467,475 MHz

RXINJ

RX injection signal to the double balanced
mixer

12.8 MHz

12.8 MHz signal to the multiplier for the
2.mixer

VRX

RX operating voltage 4.75 V from the regula-
tor

450 kHz

Output from 2. IF to the AFC detector

RXAUDIO

Receiver audio output 100mVrms

RSSI

Received signal strength indicator output
0,5...2V

channel

RF input

SINAD psof.

001

-113 dBm

20 dB

180

-113 dBm

20 dB