Interface specifications, Rs-232c, Data format – Sanyo DSR-3016 User Manual

Page 92: Communication protocol, Rs-485 data format

Advertising
background image

INTERFACE SPECIFICATIONS

RS-232C

9-pin connector specifications

Pin No.

Signal

Operation

Signal direction

1

2

RXD

Receive data

Computer

Digital video

recorder

3

TXD

Transmit data

Digital video recorder

Computer

4

5

GND

Ground

6

7

RTS

Request to

send

Digital video recorder

Computer

8

9

Data format

Mode

Asynchronous

Character length

8 bits

Data transmit speed

2400, 4800, 9600, 19200 bps

Parity

None

Stop bit

1

Communication protocol

Communication is carried out in units of 1 byte. After the computer
transmits one byte of data, it waits for a response from the digital
video recorder, and then transmits the next byte of data.

To start sending commands, an ON (F6) command is sent. The digital
video recorder will continue to receive commands until an OFF (F7)
command is sent to stop. The digital video recorder sends an ACK
(OA)
each time it receives a command.

See Table 4 - Command Table on page 71.

RS-485

Data format

Mode

Asynchronous

Character length

8 bits

Data transmit speed

2400, 4800, 9600, 19200 bps

Parity

None

Stop bit

1

Communication protocol

A proprietary Sanyo protocol (SSP: Security Serial Protocol) is used. It
is recommended that a special controller be used. Contact the place
of purchase for further details on obtaining a special controller.

RS485 termination switch settings (RS485
TERMINATE)

Termination setting

If several unit are being connected together, termination settings must
also be made.

Set the RS485 termination switch on the rear panel to ON, and set
the termination switch of the last device in the series to ON.

Be sure to set the RS485 termination switches of all devices in
between (devices other than the first and last in the series) to OFF.

Note: If the termination settings are not correct, data will be reflected

by either end of the series and this will affect the transmission
of other data, so that the data that is transmitted to each device
will not be correct.

(Example)

9

8

7

6

5

4

3

2

1

12V DC IN

POWER

ON

OFF

RS485

GND

1
0

A

A

B

B

ADDRESS

TERMINATE

1 2 3

Digital video recorder

Digital video recorder

Termination switch

OFF

ON

System controller

OFF

ON

RS485

TERMINATE

OFF

ON

RS485

TERMINATE

English

91

Advertising