Schumacher XI41DU User Manual

Page 10

Advertising
background image

• 7 •

LEd diSPLAY

7.

The LED display identifies the current status of the inverter.
VOLTS iN

: The voltage of the vehicle’s battery, Portable Power jump starter or

DC power source.
VOLTS OUT : The voltage supplied to the device through the AC receptacle.
WATTAGE OUT : The power or wattage supplied to the device plugged into the

inverter.
An audio alarm will sound when any of the following codes display. To stop the
alarm, press the ON/OFF switch:



– The inverter is not functional. See warranty and call Customer Service

1-800-621-5485 (Hours: 7:00 am to 5:00 pm CST).


– The vehicle’s battery voltage is more than 15.5-volts. The inverter will

automatically restart after the voltage drops below 15.0-volts.


– The continuous load demand from the device exceeds the inverter’s

wattage output.


– The inverter is overheated and automatically turns off for a period

of 1 to 3 minutes to cool. Make sure the inverter is well ventilated. It will

automatically restart after it cools.


– The vehicle’s battery voltage is less than 10.5-volts.



– Short circuit, power surge or overload in the device.

iF THE iNVERTER FUSE BLOWS

8.

Your power inverter is fitted with a fuse, which should not have to be replaced under

normal operating conditions. A blown fuse is usually caused by reverse polarity or a

short circuit within the device or equipment being operated.
If the fuse does blow, take the inverter to a qualified technician for repair.