Schumacher XI41DU User Manual

Page 13

Advertising
background image

• 10 •

Model: Xi50dU

Maximum Continuous Output ---------------------------------------------------------- 500 Watts

Surge Capability (0.1 second) -------------------------------------------------------- 1000 Watts

No Load Current Draw ------------------------------------------------------------------------- <0.5A

Output Wave Form ----------------------------------------------------------- Modified Sine Wave

Input Voltage Range ----------------------------------------------------------- 10.5V – 15.5V DC

Output Voltage Range -------------------------------------------------------------- 120V ± 5% AC

Low Battery Alarm ------------------------------------------------------- Audible, 11V ± 0.3V DC

Low Voltage Shut Off ------------------------------------------------------------ 10.5V ± 0.3V DC

Over Voltage Shutdown --------------------------------------------------------- 15.5V ± 0.5V DC

Optimum Efficiency ------------------------------------------------------------------------------- 85%

AC Receptacle ------------------------------------------------------------ Two, NEMA 5 - 15 USA

USB Port -------------------------------------------------------------------- One, USB 5V 0.5 Amp

Dimensions --------------------------------------------------------------------- 5” L x 4” W x 2.2” H

Weight --------------------------------------------------------------------------- approximately 2 lbs.
Model: Xi75dU

Maximum Continuous Output ---------------------------------------------------------- 750 Watts

Surge Capability (0.1 second) -------------------------------------------------------- 1500 Watts

No Load Current Draw ------------------------------------------------------------------------- <0.5A

Output Wave Form ----------------------------------------------------------- Modified Sine Wave

Input Voltage Range ----------------------------------------------------------- 10.5V – 15.5V DC

Output Voltage Range -------------------------------------------------------------- 120V ± 5% AC

Low Battery Alarm ------------------------------------------------------- Audible, 11V ± 0.3V DC

Low Voltage Shut Off ------------------------------------------------------------ 10.5V ± 0.3V DC

Over Voltage Shutdown --------------------------------------------------------- 15.5V ± 0.5V DC

Optimum Efficiency ------------------------------------------------------------------------------- 85%

AC Receptacle ------------------------------------------------------------ Two, NEMA 5 - 15 USA

USB Port -------------------------------------------------------------------- One, USB 5V 0.5 Amp

Dimensions ------------------------------------------------------------------- 8.5” L x 4” W x 2.2” H

Weight ------------------------------------------------------------------------ approximately 3.5 lbs.

REPLACEMENT PARTS

11.

Models Xi41dU and Xi50dU

12V Accessory Plug with Cables

2299001884

Red Battery Cable with Clamps

2299001894

Black Battery Cable with Clamps

2299001895

Model Xi75dU

12V Accessory Plug with Cables

2299001884

Red Battery Cable with Clamps

2299001892

Black Battery Cable with Clamps

2299001893

Advertising
This manual is related to the following products: