S U B - Z E R O

I C E M A C H I N E

O P E R A T I O N

O P E R AT I O N A L

C H E C K S

C U B E W E I G H T A D J U S T M E N T

The cube weight can be increased from the
factory setting by adjusting the finish time.

Additional finishing time check:

1)

Press and hold the POWER button for 5
seconds.

2)

Count the flashes on the ICE light.

The light will flash once for each additional
minute of freeze cycle time.

Adjusting finishing time:

Adjust in 1 minute increments and allow the
ice machine to run several freeze/harvest
cycles, then inspect the ice cubes. If a heavier
cube weight is desired add another minute of
freeze time and repeat the process.

1)

Press and hold the POWER button.

2)

Press and release the CLEAN button once
for each additional minute of freeze cycle
time desired.

3)

Five minutes is the maximum additional
freeze time that can be added. Pressing the
CLEAN button 6 times will reset the finish-
ing time to zero additional minutes.

Cube weight increases or decreases
depending on the amount of dimple
in the cube