P R O B L E M

P O S S I B L E C A U S E

P O S S I B L E S O L U T I O N

Ice machine will

No electrical power to the

Replace the fuse, reset the breaker,

not run

ice machine

turn on the main switch or plug in
ice machine.

POWER

button has not been

Refer to page 19 and activate the

depressed

ice machine.

Bin thermostat incorrectly

Adjust bin thermostat, refer to

adjusted

page 21.

Drain pump safety switch

Verify line is not kinked or crimped

is open

then call for service.

Ice machine runs and

No water to ice machine

Correct water supply.

no ice is produced

Incorrect incoming water pressure

Water pressure must be 20–80 psi
(1.4 bar–5.5 bar).

Spray nozzles blocked with

Clean and sanitize the ice machine,

mineral buildup

refer to pages 23–25.

Ambient temperature is too high

Ambient temperature must be

or low

between 50–100°F (10–38°C) for
models UC-15I and UC-15IP, and
between 50–110°F (10–43°C) for
models UC-15IO and UC-15IPO.

Water filter is clogged

Complete semi-annual maintenance,
refer page 23.