Desktop or shelf mounting, Desktop or shelf mounting -5 – SMC Networks 1000 User Manual

Page 33

Advertising
background image

I

NSTALLING

THE

S

WITCH

3-5

4. If installing multiple switches, mount them in the rack, one

below the other, in any order.

5. If also installing RPUs, mount them in the rack below the other

devices.

Desktop or Shelf Mounting

1. Attach the four adhesive feet to the bottom of the first switch.

Figure 3-3. Attaching the Adhesive Feet

2. Set the device on a flat surface near an AC power source,

making sure there are at least two inches of space on all sides
for proper air flow.

3. If installing a single switch only, go to “Connecting to a Power

Source” at the end of this chapter.

4. If installing multiple switches, attach four adhesive feet to each

one. Place each device squarely on top of the one below, in
any order.

5. If also installing RPUs, place them close to the stack.