11 of 20, W.c.u – Security Systems TS2000 User Manual

Page 11

Advertising
background image

TS2000

496529 Issue A

11 of 20

TS2000

Settle

RV

SPKR

ACCESS

OUT

LX

OUT

WARD

CONTROL

0V

+12V

WARD SET
WARD EXIT
SET FAIL
WARD ALARM

To nc contacts of

Access device*

To nc contacts of

Last Exit device

To nc contacts of

Exit Terminator*

To NU/REM o/p C
To NU/REM o/p B

To NU/REM o/p A

To NU/REM o/p D

* = options

Power supply must be sufficient

to power the Loudspeaker (1A).

Do not use Network power.

Connect 0V to Network 0V.

12V power

supply input

To NU/REM Cct A.

A+ and I/P A

To NU/REM Cct B.

B+ and I/P B

To NU/REM Cct C.

C+ and I/P C

To Loudspeaker

Connect other side to 0V

Programme Outputs as Ward X Outputs:

A = Set Fail

C = Set

B = Exit

D = Alarm

Programme circuits in ward X

A = Ward Control

B & C = Night

Terminals

WCU

LK

LK

Exit Mode

Exit

RV

Entry

RV

Link 1

Link 2

Timed Set

Last Exit Set*

Last Exit Set

Exit Terminator Set*

Open

Closed

* Only if link 1 is closed

Timers:

RV = Entry Time 0 - 255 secs

RV = Exit Time 0 - 255 secs

RV = Exit Settling Time 0 - 40 secs

W.C.U

EXIT

TERMINATE

LAST

EXIT

ACCESS

3

2

1

2

1

1

2

3

Figure 9 TS2000 Ward Control Unit - Connections

Figure 10. Ward Control Unit - Layout and Settings