Key functions, 13 of 20, Engineer reset – Security Systems TS2000 User Manual

Page 13: Loading defaults, Bell test/walk test, Control panel links fuses

Advertising
background image

TS2000

Key Functions

Engineer Reset

1.

Enter your engineer’s code default 1234, you are

now in Engineer’s Mode

2.

Press 0 in quit to unset.

Loading Defaults

1.

Power down panel battery and mains, close LK2

2.

Power up panel battery and mains

3.

Enter 1234 and open LK2

4.

The panel is back to Factory Default Programming.

Bell Test/Walk Test

Please refer to page 19

Memory Default Values

When a CP is shipped from the factory the memory data

default parameters are set to:

1.

Circuits: The Type and Attributes Parameters set will

depend upon the number of circuits detected;

2.

Passcodes: Engineer 1234: Master 5678: Others

unspecified;

3.

Timers: Exit 25 secs: Exit Settling 5 secs: First Entry 30

secs: Second entry 30 seconds: Bell delay 5 mins:

Bell Duration 20 mins: Comms Delay 1.5 mins: Lights

Off 5 secs: Mains Off 10 secs: Menu Timeout 30 secs:

Double Knock 10 secs.

These values will also be restored if a Factory Restart

occurs.

Control Panel Links

Fuses

496529 Issue A

13 of 20

TS2000

Link

Functions

LK1

Open: Printer to monitor Network

activity

Closed: Normal; Printer normal

and responds to keypad

commands

LK2

Open: Normal; On-site restart at

power up

Closed:Factory restart at power

up

LK3

DC3 Monitor; Leave closed

JP5

Normally fitted with links

Remove and fit Engineer’s REM if

required.

JP9

Open: Novram battery isolated

Closed: Normal; Novram battery

connected

JP13

Open: Normal

Closed: Soft reset

Fuse

Value

Use

PSU F1

1AQB

Low voltage

ac input

PSU F2

2A QB

12V external

(auxiliary)

supply

Fuseholder

1A QB

Network 12V

supply

Fused terminal

Block

1A

Mains input