TS2000

Programmable Ouputs

The programmable outputs from the NU and the REM,

are referred to as the Node Outputs

and are activated in

response to various conditions or events. They are

programmed to respond to System, Ward or Circuit

activation.

Panel outputs are from the CP and are programmed in

the same way as the Node outputs. Outputs 1

to 8 are

from the Parallel Interface Board, if fitted, and 9 to 16

are for the DC3 or DC3M Digicom if fitted.

The System activated outputs may be allocated to any

Node (NU or REM) output or the Panel (CP) outputs. They

are designated by their function and may be

programmed to be active if required. The following are

available:
(1)

Alarm: A system alarm is present;

(2)

P. A.: A Personal Attack circuit or a Duress Alarm

has been activated;

(3)

Set: The system is Set;

(4)

Fire: A Fire circuit has been activated;

(5)

Medical: A Medical circuit has been activated;

(6)

Tamper: A Tamper alarm is present;

(7)

Aux: An Auxiliary circuit has been activated;

(8)

Set Fail: An attempt to set the system has failed;

(9)

Site Engr: The Engineer’s passcode has been

entered. The output will remain active until a

User passcode is entered;

(10) Lock-Alarm:

The system has not been Set before

the start of the Time Lock period;

(11) Test-Fail: A test failure has occurred;

(12) AC Alarm: The mains supply to the PSU has not

been present for the mains fail time period;

(13)

AC Off: The mains supply to the PSU is not

present or there is no 12V output;

(14) Batt Fault: During the PSU test or while the mains

is off the PSU Battery voltage is low.

(15) Bell: The CP bell output is activated;

(16) Strobe: The CP strobe output is activated;

(17) Switch +12: The system is Set and is not in

alarm;

(18) Walk Test +: A Walk Test is in progress (use output

A or B);

(19) Walk Test –:

A

Walk Test is in progress (use output

C or D);

(20) Line Fault: A Digicom telephone line fault is

present;

(21) Time Switch: The programmed Time Switch is

active;

(22) Time Locked: The system has been Time Locked

and cannot be unset;

(23) Entry Mode: Entry mode has been initiated;

(24) 2nd Entry: The first Entry time has timed out

before a passcode entry

(25) Exit Mode: System Exit procedure has been

initiated;

(26) Exit Setting: Final Exit setting is in progress

(27) Exit Error: An error occurred during the exit

procedure and the system cannot set

(28) Lock Alert: The programmed Time Lock period is

about to start;

(29) Fire/Viper: Will provide 12V (100mA source) to

devices which latch when activated and which

are unlatched when power is removed. The

output is removed for about 3 seconds when

unsetting the system after an alarm at the

second passcode entry;

(30) PSU Test: Connected to remote PSU to initiate a

battery test;

CAUTION: It

is essential to ensure that the correct

outputs that will source (supply) or sink (accept) current

are selected to match the function required.

Menus Listing in Sequence

NOTES:

Users will enter menus at Menu 1

Engineer will enter menus at Menu 15

User Level 5 (Standard W) can only set and unset

designated wards

Instant access to Menus from a keyboard number

entry applies to Menus 1 to 9 only

Menu 2 is only available if a Ward is Set;

Menu 7 is only available if there are circuits with

attribute omit

Menu 9 is only available if a printer is connected

or the SIB is fitted

Menu 17 is only available if a Ward is defined

Menu 24 is only available if a DC3(M) is fitted

Menu 25 is only available if Engineer Reset is

programmed and a reset is required

(Passcode) Levels:
1 Engineer

2 Master

3 Manager

4 Standard S

5 Standard W

6 Restricted

TS2000

18 of 20