Aligning.miter.gauge. body – Woodstock SHOP FOX W1706 User Manual

Page 22

Advertising
background image

-20-

Model W1706 (Mfg. Since 3/13)

SE

TU

P

Aligning.Miter.Gauge.

Body

To ensure accurate cutting results when using the miter

gauge, the miter gauge body must be aligned with the

blade.

Tools.Needed.

Qty

Machinist's Square ..............................................1

Phillips Screwdriver.............................................1

To.align.the.miter.gauge.body,.do.these.steps:

1.. Install the widest blade possible, then make sure the

blade is properly tensioned (refer to

Page.17) and is

tracking correctly (refer to

Page.14).

2. DISCONNECT BANDSAW FROM POWER!

3. Make sure the table is properly aligned with the

blade (refer to

Page.19).

4. Lay the machinist's square flat on the table and up

against the blade without touching any blade teeth

(see

Figure.23 for an example).

5. Without moving the square, bring the miter gauge

body up to the square.

— If there are no gaps between the miter gauge body

and the square, no adjustments are needed.

— If there are gaps between the miter gauge body

and the square, continue with this procedure.

6. Loosen the miter gauge lock knob and rotate the

gauge body until it is flat against the square, then

re-tighten the lock knob.

7. Loosen the screw that secures the miter gauge

pointer, set the pointer to the 0° mark on the scale,

then re-tighten the screw.

Figure.23. Aligning the miter gauge body

with the blade.

Advertising