2 technical specifications of the els tp40m – Siemens Electrical Lean Switch User Manual

Page 84

Advertising
background image

Technical Specifications

Industrial Ethernet

84

A5E00152007-03

7.2 Technical Specifications of the ELS TP40M

Attachments

Attachment of DTEs or Network
Components over Twisted Pair

2 x RJ-45 jacks with MDI-X pinning
10/100 Mbps (half/full duplex)

Attachment of Industrial Ethernet FC
TP cables

2 x insulation piercing contacts with
MDI-X 10/100 Mbps (half/full duplex)

Connector for power supply

1 x 3-pin plug-in terminal block

Electrical Data

Power Supply

24 V dc supply
(18 to 32 V dc)
safety extra-low voltage (SELV)

Power loss at DC 24 V

4.8 W

Current consumption at rated voltage

200 mA

Overcurrent protection at input

PTC resettable fuse (0.6 A / 60 V)

Permitted Cable Lengths

Attachment over Industrial Ethernet FC
TP cables

100 m standard cable
85 m trailing cable
85 m marine cable

TP Connection

When using the FC Outlet RJ-45, the
following cable lengths are permitted:
100 m for standard cable
85 m for trailing cable
85 m for marine cable

Note
The number of ELS switches connected influences the frame propagation time.
When a frame passes through the ELS, it is delayed by the Store&Forward func-
tion of the switch.
-

with a frame length of 64 bytes by approximately 10

µs

-

with a frame length of 1500 bytes by approximately 130

µs

This means that the more ELS switches the frame passes through, the longer the
propagation time.