Specification – Sierra Monitor Corporation PF2A7H User Manual

Page 12

Advertising
background image

21

20

Specification

*1) With a unit selection function ( Without a unit selection function, fixed to

SI unit [ /min or , m

3

, m

3

10

3

])

*2) Flow rate indication is possible to be switched to normal condition of

0 /101.3kPa and standard condition of 20 /101.3kPa/65%RH (ANR)

PF2A703H

Flow Rate Indication/Ra

Flow rate indication range

( /min)

Indication Unit (*1, 2

Dry air

Operating fluid temp.

Linearliy

Repeatability

Model

PF2A706H

PF2A712H

125 to 3025

250 to 6050

550 to 12050

Measured min unit

( /min)

5

10

Flow rate converted
score of integrated pulse

100 /pulse

Instantaneous flow rate : /min, CFM
Integrated flow rate : , m

3

, m

3

10

3

, ft

3

, ft

3

10

3

, ft

3

10

6

0 to 50

(No condensation or freezing)

Current consumption

Mass (Weight) (*4)

1.5%F.S. or less

Temp. characteristics

Port size

1.5%F.S. or less

0.7MPa, 20

2.0%F.S. or less (0 to 50 , 25

standard)

150mA or less (No load)

1.1kg

1.3kg

2.0kg

Attachment : A6063, Packin : H-NBR, Spacer : PPS,
Mesh : SUS, Inner body : A6063, Sensor case : PPS,
Sensor : Leaded glass/ptlr/FeNi/OFC

1

1 1/2

2

Material

Detecting method

Indication digit

5digits 7segment LCD

Operation indication range

Withstanding pressure

0.1 to 1.5MPa

2.25MPa

Integrated flow rate range

Ambient temperature
range

0 to 9,999,999,999

Operation : 0 to 50

Storage : 25 to 85

(No condensation or freezing)

Output

specification

(*3)

[NPN open collector] Max. load current : 80mA,
Internal voltage drop : 1V or less (At load current
80mA), Max. input voltage : 30VA

NPN/PNP open collector (Same as

[PNP open collector] Max. load current : 80mA,
Internal voltage drop : 1.5V or less

(At load current 80mA)

Switch output

Integration pulse output

Voltage output : 1 to 5V (within rated flow range)

Linearliy : 3% .S. or less
Permissible load impedance : 100k

or more

Current output : 4 to 20mA (within rated flow range)

Linearliy : 3%F.S. or less
Permissible load impedance : 250

or more

Analog output

Response time

1s or less

Power supply voltage

Hysteresis mode : Variable (Settable starting 0)
Window comparator mode : Set for 0 to 3%F.S.

24VDC, ripple 10% or less

Withstand voltage

1000VAC, 1minute (between lead block and case)

Insulation resistance

Noise resistance

50M

or less (at 500VDC M)

(between lead block and case)

1000Vp-p pulse width 1 s first transition 1ns

Vibration proof

10 to 500Hz smaller one 1.5mm or 98m/s

2

, double

amplitude, each in directions of X,Y and Z 2hours

Impact proof

490m/s

2

, 3 tomes each in directions of X,Y and Z

Enclosure

IP65

Set flow rate range

( /min)

125 to 3025

250 to 6050

550 to 12050

Measured flow rate range

( /min)

150 to 3000

300 to 6000

600 to 12000

Analog output

3%F.S. or less

Indicated value

PF2A703H

Model

PF2A706H

PF2A712H

Hysteresis

Thermal sensing

*3) Switch output and integrated pulse are selected at initial setting.
*4) Except lead wire.