Names and functions of individual parts, Model indication method, Body – Sierra Monitor Corporation PF2A7H User Manual

Page 4: Display part, Accessories, Piping port

Advertising
background image

5

4

Unit Specification

No Symbol: Unit selection function provided
-M: SI units fixed

Lead Wire Specification

No Symbol: Lead wire with connector 3m
N: None Lead wire with connector

PF2A7 H

Flow Rate Range

03: 150 to 3000 /min
06: 300 to 6000 /min
12: 600 to 12000 /min

NOTE1:

The revised Measurement Law of Japan
does not allow use of meters or measuring
instruments, which have a unit selection
function, in Japan.

NOTE2: The fixed unit

For instantaneous flow rate is : /min
For integrated flow rate is : , m

3

, m

3

10

3

Port Screw Type

No Symbol: Rc N: NPT F: G

Body

Flow switch sensor body.
The arrow on the side of
the body indicates the
direction of flow.

Display Part

Output ( OUT1) Lamp : Lit when OUT1 is ON.

Flickers when an overcurrent error occurs.

Flow display : Instantaneous flow, integrated flow and set value are

displayed.

Flow check display : Flickering interval varies depending on the flow.
Unit display : Selected unit is displayed. Single unit type is displayed

in SI unit ( /min or , m

3

, m

3

10

3

).

Button (UP) : Selects a mode and increases a set ON/OFF value.
Button (DOWN) : Selects a mode and decreases a set ON/OFF value.

Button (MODE) :

Changes the mode.

Button (SET)

:

Changes the mode and sets a set value.

RESET

Pressing the

and

buttonssimultaneously will activate the RESET

function. Use this
function to clear errors
when a trouble occurs.

Body

Lead wire with connector
on one end (option)

Piping Port (OUT)

Display part

Connector

Piping port
(IN)

Flow check display

Output (OUT1)

display

Button( MODE)

Button (DOWN)

Button ( UP)

Button (SET)

ANR
OUT

Unit display

Flow display

Accessories

(When no symbol is specified

for wiring in the type specification)

Lead wire with connector on one end
(3 m in length )

Names and Functions of Individual Parts

Output Specification

28: NPN open collector 1output

+ Analog output (1 to 5V)

29: NPN open collector 1output

+ Analog output (4 to 20mA)

68: PNP open collector 1output

+ Analog output (1 to 5V)

69: PNP open collector 1output

+ Analog output (4 to 20mA)

Model Indication Method

Piping Port

10: Port size 1 (Applicable for PF2A703H)
14: Port size 1 1/2 (Applicable for PF2A706H)
20: Port size 2 (Applicable for PF2A712H)

Piping port

This port connects with
pipeline. Use a pipe fitting to
connect with external pipeline.

Advertising