XLogic Multichannel Compressor Owner’s Manual

3.0 Installation

3.1

Voltage Selection

Before connecting the mains supply ensure that the
voltage range selector next to the IEC socket on the rear of
the unit is correctly set. The input setting must be
confirmed before applying power. The input module can
be configured to be one of 4 voltage settings. The setting
is indicated by a plastic pin protruding through the
appropriate hole in the fuse panel - the example shown here is set for 240V operation.

The setting is altered by a small vertical PCB which can be fitted in 4 positions. To change the setting:

• Switch off and remove the IEC lead.

• Using a small flat-bladed screwdriver, lever open the fuse panel to the right of the connector.

• At the right hand side is a vertical PCB with a plastic key which indicates the setting. Using pliers, pull

out the PCB.

• The PCB has to be rotated until the

desired voltage is shown along the
edge which plugs into the module.
The plastic key (and this bit is quite
fiddly) must also be rotated so that it
points out of the module so that the
round pin aligns with the appropriate
hole in the cover panel; (refer to the
adjacent illustrations).

Note. Where the mains voltage is a nominal 230V, the ‘240V Setting’ should be used – not the ‘230V Setting’!

• Re-insert the PCB and replace the fuse panel. The plastic pin should project through the appropriate

hole.

3.2

Mounting

The XLogic unit is designed to be rack mounted. It is 2 RU (89mm/3.5 inches) high. Its depth is:

325 mm/12.8 inches not including heatsink
365 mm/14.3 inches including heatsink
400 mm/15.75 inches including connectors

The unit must be mounted on suitable rack shelves: do not rely on the rack mounting ears alone.

A 1RU space should be left above each unit to ensure adequate ventilation.

3.3

Connection

The unit has six input XLRs (female) and six output XLRs (male). Connect the inputs to the main output
insert sends of your console or to your workstation outputs. Connect the outputs to the corresponding
insert returns or to your workstation inputs.

When the unit is switched off the input XLRs are linked to the output XLRs by relays, so the unit will pass
signal even when switched off. There is a 3 second delay after switching on before the bypass relays are
energised to allow the power rails to settle, thus avoiding unpleasant thumps and pops on your
monitoring.

Note that when switched off the DC coupled input stage of the XLogic Multichannel Compressor can load
the output stages of some devices, causing low level distortion. For this reason it is not advisable to leave
the unit connected and switched off.

Once the unit is connected switch it on, then route signal to each channel in turn and check that the correct
signal LED lights yellow in the MAX display and that the signal is returned to the correct input on your
console or workstation.

100V

120V

2 3 0V

2 4 0V

24

0

1 2 0

100

240

2 3 0

120

10

0

2 4 0

230

12

0

100

240

23

0

1 0 0

100V Setting

120V Setting

230V Setting

240V Setting

(use for 90-105V)

(use for 105-125V)

(do not use)

(use for 220-240V)

Advertising