6-11

Troubleshooting

10. If the VRC 6940 has EMS, use the arrow keys to specify the range to transfer. This

prompt only appears if EMS is installed. Then press ENTER.

Figure 6-7. Selecting a Range of EMS to Transfer

11. The terminal displays the ranges you selected. Verify that they are correct.

Figure 6-

8

shows an example of what you might see. If the values are correct, press ENTER.

If the values are not correct, press CLEAR to clear the fields, then select new values.

Figure 6-8. Verifying Memory Transfer Settings

12. Next, the VRC 6940 prompts you to set communications parameters. Use UP or

DOWN arrows to select communications settings. The defaults are 9600 bps, 7 data
bits and odd parity. Xon/xoff flow control may be necessary at 38400 bps. Select the
parameters so that they match those used by RCVHEX on the Host PC.

EMS

Use arrow keys

Start End

RAM 0000 9FFF

NVM B135 DFFF

EMS None

Correct? <ENT>