4 verifying the link rate setting, Verifying the link rate setting 30, Figure 3-17 – Sun Microsystems SUN STOREDGETM 5310 NAS User Manual

Page 230: Setti

Advertising
background image

3-30

Sun StorEdge 5310 NAS Troubleshooting Guide • December 2004

6. If applicable, repeat for all other modules in the storage array.

End Of Procedure

FIGURE 3-17

Setting the Tray ID Switch

3.2.4

Verifying the Link Rate Setting

Use the following procedure to verify the Link Rate setting if a link rate problem is
indicated. Figure 3-18 shows the location of the Link Rate switch.

Caution –

Electrostatic discharge damage to sensitive components. To prevent

electrostatic discharge damage to the module, use proper antistatic protection when
handling the module components.

1. Put on antistatic protection.

2. Remove the screw and the switch cover from the Link Rate switch.

3. Verify that the Link Rate Switch is set to 2 Gb/s.

The Link Rate switch is not active. This switch is pre-set to 2 Gb/s at the factory, and
defaults to 2 Gb/s.