The SZ Series Protection Circuitry

As noted in the “Guided Tour” section of this manual, the SZ Series front-panel

Protection LED indicates the activity of the relay speaker connection circuitry. When

the Protection LED is lit, this circuitry is active, and all connected speakers are muted.

The following conditions will cause the Protection LED to go on:

• Initial power-up: For approximately five seconds after initial power-up, the protec-

tion circuitry is activated and the speaker outputs are muted. If everything is operat-

ing normally, the SZ Series begins delivering signal to connected speakers (at which

point you’ll hear the click). It is normal for the Protection LED to fade gradually after

the amplifier is powered off.

Overheating: A temperature sensing device in the SZ Series will cause the protection

circuitry to be activated (and the Protection LED to go on) whenever the operating

temperature of the unit rises above a safe level. To guard against this problem, make

sure the SZ Series receives adequate ventilation on all sides and that both the front

and rear panels are unobstructed.

• Severe over current conditions: This occurs whenever the signal being output from

the SZ Series rises to a level above 20% THD (Total Harmonic Distortion).

• Shorted speaker cables: This will occur if, due to faulty wiring, the hot and ground sig-

nals being output by the SZ Series are shorted to one another.

• Output impedance drops below 2 ohms: This can occur if the SZ Series is connected to

inappropriate speaker systems (see the “Setting Up and Using Your SZ Series” section

on page 10 in this manual for more information).

In general, any time the Protection LED lights up (other than during the approxi-

mately five seconds following initial power-up), there is reason to be concerned. If this

occurs, turn the SZ Series off immediately and carefully check all wiring and external

devices in order to locate and correct the condition that caused the LED to light up in

the first place.

For further assistance, contact your local Samson dealer. If purchased in the United

States, you can call Samson Technical Support (1-800-372-6766) between 9 AM and 5

PM EST.

WARNING: If the Protection LED fails to go out (and you fail to hear the accom-

panying audible click) approximately five seconds after power-up, turn the SZ

Series off immediately and check all external devices and wiring for possible

shorts or other defects.