Sz series layout - rear panel – Samson POWER AMPLIFERS SZ1120 User Manual

Page 8

Advertising
background image

4

SZ Series Layout - Rear Panel

1: AC INPUT - Connect the supplied heavy-gauge 3-pin “IEC” power cable here.

2: DC 24V INPUT – A two circuit Euroblock socket is provided for connecting 24 volt emergency back-up

power.

3: CONSTANT VOLTAGE (output connector) - Use this Euroblock to connect the amplifier to one of the

25, 70 and 100 volt outputs if you are using a constant voltage system. See page 13 in this manual for more

information about wiring and interconnection instructions.

4: LOW-Z (output connector) - Use this Euroblock to connect the amplifier to a 4 ohm speaker. See page 13

in this manual for more information about wiring and interconnection instructions.

5: LEVEL ADJUST- This control knob provides input level adjustment from -12dB to 0dB.

6: HPF (HIGH PASS FILTER) – Selectable High Pass, or low cut, filter at 400Hz used when powering outdoor

announcement horn speakers.

7: INPUT – XLR connector for balanced line level input.

8: LINK – Female XLR connector for connecting additional amplifiers.

9: GROUND LIFT - Used to float the audio ground from the chassis ground.

10: Rear Vents – Used in combination with the internal fan and front vents to dispel warm air ensuring

reliable operation.

WARNING!: Each of the SZ Series amplifiers can run only one output configuration at the same time.

Operating SZ series amplifers using 4 ohm and 25, 70 or 100 volt concurrently may cause damage to

the amplifier or connected speakers, and may void your warranty.

Advertising