Install the SCM in the shelf

5

Install the SCM in the shelf

1. Follow ESD precautions and make sure you are

adequately grounded before handling the transceivers
and the SCM.

2. Remove the SCM from its antistatic bag.

3. Open both ejector latches outward.

W

ARNING

!

Never force open an ejector latch. Press the

inner latch all the way in before you pull out the handle.

If the latch does not open fully, close the latch and try

again, making sure the inner latch is fully depressed.

4. Slide the SCM into one of the hub slots on the shelf.

The table below show the hub slots for RadiSys shelves.
If installing the SCM in a non-RadiSys shelf, refer to the
documentation for that shelf.

Note: These are the physical slot numbers.

If correctly aligned, the edges of the SCM fit within the
narrow guide rails of the shelf.

W

ARNING

!

Do not force the SCM into the slot:

ƒ

To avoid damage to connectors, make sure the rear

slot is either empty or contains a module compatible

with the SCM.

ƒ

If the SCM does not slide easily, make sure you are

inserting the SCM into the correct slot and that it is

aligned properly.

5. Once the SCM is inserted all the way into the shelf, simultaneously close both ejector latches

inward. This seats the SCM’s connectors into the shelf’s backplane.

The hot-swap (H/S) LED light flashes until the SCM is fully powered. Once powered, the LED light
turns off.

If the LED remains solid blue or keeps flashing after the SCM is inserted, it indicates the installation
has failed. Please see the ATCA-2210 Switch and Control Module Reference for more information.

6. Secure the SCM in its slot by hand tightening the two fastening screws on each end of the

module’s front panel.

7. Repeat these steps if you are installing a second SCM in the remaining hub slot. Installing two

SCMs on the shelf allows for redundancy—a means of providing continuous system functionality
even if a failure occurs on one of the SCMs.

RadiSys shelf

Hub slots

ATCA-6000, 12U 14-slot

7

8

ATCA-6006, 5U, 6-slot

1

2

ATCA-6014, 13U 14-slot

7

8

ATCA-6016, 13U 16-slot

8

9

Open position

b) pull out

a) push inner latch
in all the way

Closed position

push in