Installation Guide

6

Connect to the SCM

The SCM can be accessed by an external computer through the serial and the Ethernet maintenance
ports. Use the serial port to perform diagnostic and verification procedures or to enable or disable the
Shelf Manager. Use the Ethernet maintenance port to connect the SCM to the network and to perform
configuration procedures.

Note: If you have two SCMs installed, connect to each one separately.

Connect to the serial port

1. Connect the included serial port cable by plugging one

end into the RJ-45 serial port labeled “LMP SER” on the
SCM.

2. Connect the cable’s other end to the COM1 or the COM2

serial port of an external computer, such as a laptop.

3. Start a terminal-emulator application, such as Procomm

Plus® or minicom, from the operating system on your
computer or laptop. Specify 115,200 baud, 8 data bits,
no parity, one stop bit, and no hardware or software flow
control.

4. Press the Enter key and verify you get a login prompt.

Enter admin at the prompt.

5. Verify that you receive a welcome message and a prompt

showing ATCA-2210#.

Important: If the SCM has been installed in a non-
RadiSys shelf, you may receive a DEBUGMODE prompt
rather than the ATCA-2210 prompt. If this occurs, disable the SCM’s on-board Shelf Manager. See

Disable the Shelf Manager on the SCM

on page 10

for more information.

Connect to the Ethernet maintenance port

1. Connect a crossover Ethernet cable between the SCM’s Ethernet maintenance port, which is

labeled “LMP ETH,” and a Linux host computer that is connected to your network.

2. Configure the computer to a subnet IP address (10.0.0.x) and set the netmask to 255.255.255.0.

3. On the computer, verify Telnet access to IP address 10.0.0.1 (port 23).

4. At the login prompt, enter admin and verify you receive the

ATCA-2210#

prompt. To log off the

SCM at any time, enter the exit command.

Note: To connect to the Linux shell on the SCM, use either a serial port or Telnet connection. After
connecting, log in as root and enter ifconfig to view eth0 configuration settings.