Troubleshooting, User guide troubleshooting – Sierra Wireless 350 User Manual

Page 11

Advertising
background image

o

Welcome

o

Installation

o

Using AirBooster

o Troubleshooting

o

Service

o

Contact Us

User Guide

Troubleshooting

For the most up-to-date and detailed troubleshooting tips, visit the Sierra
Wireless

AirBooster 350 website

. There is a separate section for

troubleshooting GPS issues

.

The most common cause of problems with the AirBooster 350 RF amplifier is
with connectors and cables. Always check the connectors before calling

Technical Support

.

Problem

Suggestion

CDPD device can receive but not
transmit.

STATUS indicator fails to light
when CDPD device is connected.

The device is either not supported by
the booster, or has had its booster
support capability switched off
(+WS214).

Verify that the CDPD device is a
supported model and revision, and is
on (enabled).

STATUS indicator is working
normally but CDPD device fails to
register, receive, or transmit.

Coverage may be unavailable in the
current location.

Verify the antenna connection is
secure and cable is unbroken. Try
another antenna.

STATUS indicator is dim or
flickering. CDPD device is losing
packets or appears to have slower
throughput or does not function at
all.

Power to the booster has dropped
below 9Vdc. Check the battery being
used to power the booster.

Disconnect the CDPD device from the
booster and use the CDPD device's
own antenna until adequate power can
be restored to the booster.