1. ALARM OUT
Alarm out jack for motion detection. (Open Collector, On Gnd)

2. GND
Grounding jack.

3. TRIGGER IN (SCC-C4239P/C4339P)

Displays the current still image when it receives the Trigger signal. (Normal

Open Type)

4.5.6 FOCUS, COM, ZOOM

This port is used for ZOOM/FOCUS, MENU CONTROL, HOME
RETURN, and ONEAF by using an external controller.
Depending on the input condition, 4 modes, A, B, C, and D are
available. (SPECIAL - CTRL TYPE)
(Operation Voltage Range : +3V~+13V, -3V~-13V)

1) When the voltage is supplied to either ZOOM or FOCUS port

Function
*1

Code

Tele(Up)

Wide(Down)

Near(Left)

Far(Right)

ZOOM Port

FOCUS Port

A

-6V

+6V

-6V

+6V

B

-6V

+6V

+6V

-6V

C

+6V

-6V

-6V

+6V

D

+6V

-6V

+6V