Excessive Steam Coming from Pressure Relief Vent

Excessive steam coming from pressure relief vent.

DISCONNECT POWER AT CIRCUIT BREAKER.

Check pressure switch for proper operation (see Figure 17 on page 34).

Pressure switch OK?

No

Replace pressure switch.

Yes

Remove control panel, but leave plug connected.

Check controller (see Figure 15 on page 32).

Controller OK?

Check contactor and

replace as necessary

(see Figure 11 on page

28).

Yes

No

Replace controller.