Roubleshooting, Sez s, Service request” light comes on during operation – Southbend SEZ/3 User Manual

Page 22

Advertising
background image

T

ROUBLESHOOTING

SEZ S

ERIES

C

OUNTERTOP

S

TEAMERS

P

AGE

22

O

PERATOR

S

M

ANUAL

1183437

TROU

BLE

S

H

OOTI

N

G

“Service Request” Light Comes On During Operation

“Service Request” light comes on during operation.

Is water level

at normal level

in cavity?

Yes

No

Check for adequate water pressure to unit.

DISCONNECT POWER AT CIRCUIT BREAKER.

Check controller (see Figure 15 on page 32).

DISCONNECT POWER AT CIRCUIT BREAKER.

Turn unit off and check that unit drains fully.

Open door. Turn unit back on and wait 20 minutes.

Replace controller.

Yes

No

Check water solenoid (see Figure 16 on page 33).

Controller OK?

Water solenoid OK?

Replace

water solenoid.

Yes

No

Remove screen from strainer and clean or replace

as necessary. Reassemble, reconnect, and recheck

the steamer. If the Service Request light still comes

on, examine the following for obstructions or

deposits: pressure regulator, solenoid, and check

valve. Clean or replace as necessary.

Check high-limit thermostats

(see Figure 18 on page 35).

Replace high-limit

thermostats

as necessary.

Check controller (see Figure 15 on page 32) and

replace as necessary.

High-limit

thermostats

OK?

No

Yes

Advertising