Unit Not Heating Up, “ON” Light Not Lit

Unit not heating up, “ON” light not lit.

Check that circuit breaker is ON and that proper voltage

is available at main fuse block.

DISCONNECT POWER AT CIRCUIT BREAKER.

Remove control panel without disconnecting plug.

Reconnect power.

Turn lever to “ON” position. Actuate door switch.

Check voltage between A and B on control panel fuse

block (see Figure 7 on page 24).

DISCONNECT POWER AT CIRCUIT BREAKER.

Check voltage on side C and D on control panel

fuse block (see Figure 7 on page 24).

Check resistance between contactor terminals

(see Figure 8 on page 25).

Is

measured resistance

consistent with the table

in Figure 8 on

page 25)?

Check main fuses and

replace as needed

(see Figure 9 on page

26).

Replace elements

and main fuses

(see Figure 9 on page

26).

No

Yes

Check for short circuit in

power switch (see

Figure 10 on page 27),

contactor and MOV

(see Figure 11 on page

28), and buzzer (see

Figure 12 on page 29).
Replace as necessary.

Check voltage across

terminals 1 and 2 of

terminal block (see

Figure 7 on page 24).

Yes

No

Replace control panel

fuses.

Replace “ON” light;

continue on next page.

Test power switch or adjust so

that it is actuated properly by
cam on valve shaft. Replace

switch as necessary

(see Figure 10 on page 27).

No

Yes

Does voltage

match serial plate

voltage?

No

Yes

Does voltage

match serial plate

voltage?

Does voltage

match serial plate

voltage?