Instructions for the installer, 4 regulation of primary air, Referred to distance “ a ” in mm – Smeg SER63LPG User Manual
Page 11: Auxiliary (1) 2.5, Semirapid r (2) 2.0, Semirapid l (3) 1.5, Rapid large (4) 2.5, Semirapid (2) 2.0, Rapid (3) 1.5, Fish burner (4) 8.0
Advertising
Instructions for the installer
13
5.4
Regulation of primary air
Referred to distance “A” in mm.
60 cm hobs with separable control panel.
Burner
LPG
Auxiliary (1)
2.5
Semirapid r (2)
2.0
Semirapid l (3)
1.5
Rapid large (4)
2.5
Ultrarapid (5)
open
90 cm hobs with separable control panel.
Burner
LPG
Auxiliary (1)
2.5
Semirapid (2)
2.0
Rapid (3)
1.5
Fish burner (4)
8.0
Ultrarapid (5)
5.5
60 cm hob with built-in control panel.
Burner
LPG
Auxiliary (1)
2.5
Semirapid r (2)
2.5
Semirapid l (3)
2.0
Rapid medio (4)
2.5
Ultrarapid (5)
3.0
Advertising