Instructions for the installer

14

6

FINAL OPERATIONS

Having carried out the above adjustments, reassemble the appliance

following, backwards, the instructions in paragraph “5.1 Removing the
separable control panel

/ 5.2 Removing the hob”.

6.1

Regulation of minimum for natural gas

Replace the components on the burner and

slide the knobs on the gas tap pins. Light the
burner and set it at minimum position. Remove
the knob and turn the regulation screw inside or
next to the gas tap pin (depending on the
model) until you get a suitable minimum flame.
Replace the knob and check burner flame
stability: (rapidly turning the knob from
maximum to minimum position, the flame
should not go out).

6.2

Regulation of minimum for LPG

To regulate the minimum for LPG, completely tighten (clockwise) the

screw inside or next to the gas tap pin (depending on the model).
The diameters of the by-passes for each burner are given in table “5.3

Regulation for LPG”.

After having regulated the device with gas other than the one tested,

replace the label located on the guard with the one that corresponds to
the new gas. The label is inside the bag that contains the nozzles
provided.