Default Replenishment Rates
Solution
Time in sec.
Replenishment rates
Developer 33
60
ml/m
2
Bleach-fixing solution
33
100 ml/m
2
Stabilizer 69
60
ml/m
2
+
140 ml/m
2
water
Calibrating the Temperature Sensors and Water Pumps
WARNING:
Calibrating the temperature sensors and water pumps presents
a potential safety hazard because it requires the wet section
cover to be open with power applied. Therefore, the following
functions should only be performed by a service technician:
•
Settings / Machine settings / PP Temperature
•
Settings / Machine settings / PP Pumps
4-28
KODAK PROFESSIONAL SRP 30 Laser Printer