Technical Data

DESCRIPTION

VOS 952-1G/953-1G

DATA

Type

VGO 939-1G

VGF 939-1G

Notes

Order no.

24410101

24410100

Locally fed

Remotely fed

FORWARD PATH

Frequency range

MHz

85-1000

Gain

dB

40

Gain setting range, interstage

³

)

dB

32-40

Amplitude response

dB

±0.5

85-1000 MHz, at 25 °C

Amplitude response (additional, 862-1000 MHz)

dB

-0.5

at 25 °C

Attenuation setting range, on input

³)

dB

0-26

Pre-emphasis setting range, at input

³)

or interstage

dB

0-26 or 0/4/8

Return loss, as of 40 MHz

dB

18-1.5/oct.

Noise figure

dB

4

at 40 dB gain

Max. operational level: CENELEC raster

¹)

dBµV

116/118

CTB: 60 dB/CSO: 60 dB (pre-emphasis 4 dB)

Hum modulation ratio

dB

-

60/70

AT 7 A, 5-65/85-1000 MHz

RETURN PATH

Frequency range

MHz

5-65

Gain (input stage bridged), active operation

dB

30 (21)

Gain, passive operation

dB

-2

Amplitude response

dB

0.5

Attenuation setting range, at input or interstage ³)

dB

0/4/8 or 0-16

Pre-emphasis setting range, interstage

dB

0/3/6

Ingress Control Switch (ICS)

dB

8/> 40

attenuated/switched-off

Max. output level at 30 and 21 dB gain

dBµV

107/116

60 dB IMod2/IMod3 (EN 60728-3/50083-5)

Max. output level

dBµV

120

According to KDG 1 TS 140 (full system load)

Input level density

dBµV/Hz

-8

CINR at 50 dB (EN 60728-3/item 4.7)

Dynamic range at 30 dB gain (5-65 MHz) ²)

dB

18

Dynamic range at 21 dB gain (5-65 MHz) ²)

dB

25

Noise figure

dB

6

NETWORK MANAGEMENT

Monitorable parameters

Internal voltage supply, internal current drain,

internal temperature, ICS switch

Test sockets

Test socket 1 (on amplifier input), bi-directional

dB

20

Test socket 2 (on amplifier output), directional coupler

dB

20

Possibility to feed in return path signals

(5-65 MHz); if button is kept pressed, the

incoming return path signal can be measured

Test socket 3 (in return path amplifier), directional coupler

dB

10

Attenuation relative to return path input

SWITCHED-MODE POWER SUPPLY

Nominal input voltage

V

AC

230

32-72

Mains frequency range

Hz

50-60

Max. remote feed current

A

-

7

per input or output

Max. remote feed current, local insertion

A

-

10

Power consumption (without monitoring)

W

17.5

Return path amplifier active

GENERAL

Classification according to KDG 1 TS 140

D(4.4)

Ambient temperature range

°C

-20 to +55

data-conform operation

RF connections

PG 11

Test sockets

F-type connector

Housing protection class (to EN 60529)

IP 54

Dimensions (W x H x D)

mm

238 Ч 86 Ч 189

Packing unit/weight

pc./kg

1(10)/2.2

1) CENELEC: 41 channels 2) When the 15 MHz high pass is connected, the dynamic range increases by 3 dB 3) Settable in 2-dB steps using slide switches

VGO 939-1G/

VGF 939-1G

• Latest GaAs-MMIC technology
• Innovative operational concept:

- Settings via slide switches

Device settings can be reproduced exactly
Fewer plug-in cards and variable attenuators
needed

-
-

• Very high output level at lowest intermodula-

tion products

• Built-in active return path with various setting

possibilities

• 15 MHz high pass can be activated in the

return path

• Ingress Control Switch (ICS)
• Monitorable with HMS or DOCSIS (option)
• Insert position for additional functions in the

forward path (e.g. de-emphasis)

• Bi-directional test socket on amplifier input

with inductive coupling

• Directional coupler test socket on amplifier

output and in return path

• Test signals can be coupled in for the return

path

• Highly efficient switched-mode power supply

unit

• VOS 952-1G - locally fed, F-type connectors
• VOS 953-1G - remotely fed (auto-supply),

F-type sockets

• Surge absorbers on all RF connections and in

switched-mode power supply unit

• Die-cast housing
• Test sockets: F-type sockets

VOS 952-1G/953-1G

House connection amplifiers

The compact, price-optimised house connection
amplifiers 952-1G and VOS 953-1G were designed
for application in modern HFC networks. Great value
was set upon a high dynamic range for Interstage
operation as well as upon a cost-efficient operation
concept with slide switches.

Monitoring via DOCSIS transponder

If fitted with the optional monitoring transponder
TVM 1000/H, the amplifiers VOS 952-1G/953-1G
can be monitored via DOCSIS protocol. Monitoring
with HMS Both amplifiers can be flexibly integrated
into monitoring systems which operate with the
widespread HMS protocol.

Bridgeable diplex filter

Bridging plugs enable variation of the frequency
range between 47-1000 MHz and 85-1000 MHz
making it possible to carry out transmission in
BAND I in the forward path (without return path).

Flexible return path

In the latest generation, the return path can be
operated either actively or passively.