Data – Kathrein VGP 9033-1G/9041 User Manual

Page 8

Advertising
background image

14

15

DATA

Technical Data

1)

Adjustable with 2 slide switches in 1 dB steps

2)

CENELEC: 42 channels

3)

When the 15 MHz high pass is connected, the dynamic range increases by 3 dB

Type

VOS 952-1G

VOS 953-1G

Notes

Order no.

24410098

24410099

Locally fed

Remotely fed

FORWARD PATH

Frequency range

MHz

47/85-1000

47/85-1000

Gain

¹)

dB

40-32

40-32

Interstage gain setting

Amplitude response

dB

±0.5

±0.5

85-1000 MHz, at 25 °C

Amplitude response (additional,
862-1000 MHz)

dB

-0.5

-0.5

at 25 °C

Attenuation setting range

dB

0-16

0-16

On amplifier input

Pre-emphasis setting range

dB

0-16 and 0/6

0-16 and 0/6

On amplifier input

and interstage

Noise figure

dB

4/5/5

4/5/5

At 40/36/32 dB gain

Max. operational level: CENELEC channel
plan

²)

dBµV

112/116

112/116

CTB: 60 dB/CSO: 60 dB (pre-

emphasis 6 dB and gain 40 dB)

Hum modulation ratio

dB

-

>60/70

RETURN PATH

Frequency range

MHz

5-65

5-65

Gain, switchable

dB

30/21

30/21

Frequency response

dB

0.5

0.5

Attenuation setting range

dB

0-16 / 0/4/8

0-16 / 0/4/8

On input/interstage

Pre-emphasis setting range

dB

0/3/6

0/3/6

Interstage

Ingress Control Switch (ICS)

dB

8/> 40

8/> 40

attenuated/switched-off

Max. output level at 30 and 21 dB gain

dBµV

107/116

107/116

60 dB IM2/IM3

(EN 60728-3/50083-5)

Maximum output level

dBµV

120

120

According to KDG 1 TS 140

(medium system load)

Input level density

dBµV/Hz

-10

-10

CINR at 50 dB (EN 60728-3/

item 4.7)

Dynamic range at 30 dB gain (5-65 MHz) ³)

dB

17

17

Dynamic range at 21 dB gain (5-65 MHz) ³)

dB

25

25

Noise figure

dB

5

5

NETWORK MANAGEMENT

Monitorable parameters

Internal supply voltage,

internal current drain,

temperature, ICS switch

Internal supply voltage,

internal current drain,

temperature, ICS switch

TEST SOCKETS

Test socket 1 (on amplifier input)

dB

20

20

5-862 MHz bi-directional,

internal

Test socket 2 (on amplifier output)

dB

20

20

5-862 MHz with directional

coupler, external - return path

signals can be fed in (5-65

MHz); if push-button is kept

pressed, the incoming return
path signal can be measured

Test socket 3 (in return path)

dB

10

10

5-65 MHz with directional

coupler, external

Type

VOS 952-1G

VOS 953-1G

Notes

Order no.

24410098

24410099

Locally fed

Remotely fed

SWITCHED-MODE POWER SUPPLY

Nominal input voltage

V AC

230

38-65

Mains frequency range

Hz

50-60

50-60

Power consumption

W

11

12

Return path amplifier active/

without monitoring

GENERAL

Ambient temperature range

°C

-20 to +55

-20 to +55

RF connections

F-type socket

F-type socket

Test sockets

F-type socket

F-type socket

Housing protection class (to EN 60529)

IP 54

IP 54

IP 54: Outdoor use in weather-

proof cabinet

Dimensions (W x H x D)

mm

225 Ч 55 Ч 155

225 Ч 55 Ч 155

Packing unit/weight

pc./kg

1(10)/1.8

1(10)/1.8

VOS 952-1G/953-1G

Advertising