SERVICE TECH. INFORMATION

SECTION 5

23

5B.

REGENERATION CYCLE TIMES

SEE REGENERATION TABLE ON PAGE 20, AND SPECIFICATIONS, PAGE 21.

CYCLE FLOW RATES (GALLONS PER MINUTE)

FILL (flow to salt storage tank)

0.3 (1.1 liters)

BRINING

.16 (.6 liters)

BRINE RINSE

(flow to drain)

.11 (.4 liters)

BACKWASH

(flow to drain)

1.8 (6.8 liters)

FAST RINSE

1.8 (6.8 liters)

TO SET

DOUBLE BACKWASH

(Softener has a backwash and fast rinse cycle before brining, and

after brining, which is beneficial on some kinds of iron bearing water):

USE BUTTONS

£

(SET/CLEAR), and

¡

(PRESENT TIME AND DAY)

1

.

Press and hold

£

entire display comes on.

. . . . . . . . . . . . . . .

"

Press

¡

to display 3 dashes

"

Press

£

to display dbl

"

Press

¡

to display 18:88

2

.

Press

£

to return present time.

REPEAT ABOVE STEPS TO CANCEL DOUBLE BACKWASH.

CYCLE SEQUENCE WITH DOUBLE BACKWASH

: 1. Fill 2. Backwash 3. Fast Rinse 4. Brining/Brine Rinse 5. Back-

wash 6. Fast Rinse — Return to Service

OTHER RECHARGE CYCLE TIME ADJUSTMENTS

Cycle times in specifications are factory settings. Do the following to check for correct cycle times.
NOTE: Removing from electrical power (varies from 6 to

15 hours) resets timer to factory programming.

DISPLAY MUST SHOW TIME AND DAY

1

.

Press and hold

£

¼ entire display

comes on.

2

.

Press

©

¼ 2:08 shows; meaning

#2 cycle (brining & br. rinse) and

80 minutes (8 x 10).

a

.

If 2:08 does show, go to step 3.

b

.

If other than 2:08 (2:00 to 2:15),

press

£

until 2:08 shows.

3

.

Press

©

¼ 3:12 shows, meaning

#3 cycle (backwash) and 12 minutes.

a

.

If 3:12 does show, go to step 4.

b

.

If other than 3:12 (3:00 to 3:30),

press

£

until 3:12 shows.

NOTE: Instead of programming a double backwash, a

longer single backwash is beneficial on some types of iron

water.

4

.

Press

©

¼ 4:04 shows; meaning

#4 cycle (fast rinse) and 4 minutes.

a

.

If 4:04 does show, go to step 5.

b

.

If other than 4:04 (4:00 to 4:30),

press

£

until 4:04 shows.

5

.

Press

©

¼ 18:88 shows.

6

.

Press

£

¼ to return to present time and day.

TO SET MINUTE —

LENGTH OF FILL CYCLE (factory setting, 8 minutes

)

USE BUTTONS

©

(RECHARGE TIME),

£

(SET/CLEAR), and

¡

(PRESENT TIME AND DAY)

1

.

Press and hold

©

until FILL shows, then 16 (factory setting).

"

Press

£

to set the desired fill minutes

(from regeneration table).

2

.

Press

¡

to return present time and day.

PM

MO

WE TH FR SA

RCHG

.

.

AM

TU

SU

PM

MO

WE TH FR SA

RCHG

.

.

AM

TU

SU

.

.

.

.

.

.

PM

MO

WE TH FR SA

RCHG

.

.

AM

TU

SU

.

.

.

.

.

.

Advertising