Service tech. information, 5c. troubleshooting – Kenmore 625.348321 User Manual

Page 24

Advertising
background image

SERVICE TECH. INFORMATION

SECTION 5

24

5C.

TROUBLESHOOTING

AUTOMATIC ELECTRONIC DIAGNOSTICS

The face plate has a self-diagnostic function for the

electrical system (except input power). The face plate

monitors the electronic components and circuits for

correct operation. If a malfunction

occurs, an error code appears in the

face plate display

.

The chart below shows the error codes that could

appear, and the possible defects for each code.

While an error code appears in the display, all face

plate buttons are inoperable except the SET button.

The SET button remains operational so the service

person can make the MANUAL ADVANCE DIAG-

NOSTICS to further isolate the defect.

CODE

POSSIBLE DEFECT

MOST LIKELY

LESS LIKELY

E— 1, E— 2,

wiring harness or connection to switch / position switch / motor inoperative / valve defect causing

E— 1, E— 2,

E— 3, E— 4

wiring harness or connection to switch / position switch / motor inoperative / valve defect causing

high torque

E— 3, E— 4

high torque

PROCEDURE FOR REMOVING ERROR CODE FROM FACE PLATE: 1. Unplug transformer 2. Correct de-

fect 3. Plug-in transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected.

FACE PLATE REPLACEMENT: Be sure the valve is in service position (observe valve cycle indicator. . . see

below) when replacingthe face plate.
If, after installing and programming the replacement face place, the valve is not in service position, do the fol-

lowing to assure correct cycle orientation, or timing, between the face plate and valve.
Use the MANUAL ADVANCE procedures, below. With the RECHARGE NOW button, advance through the

recharge cycles until the valve stops in service position, and RECHARGE no longer flashes in the timer.

NOTE: The valve motor may automatically drive through several valve positions while searching for service.

MANUAL ADVANCE DIAGNOSTIC

Use the following procedures to advance softener

valve through regeneration cycles to check opera-

tion.

Remove top cover to observe valve rotation.

DISPLAY MUST SHOW TIME AND DAY

1

.

Press and hold £ for 3 seconds

until 18:88 displays.

2

.

Press ¢ to display position (P) switch open or

closed indicator.

If the valve is in service, fill, brin-

ing, backwash or fast rinse (see

markings on cam under motor), the

display will show¼ (- -), meaning

the position switch is open.

While the valve is ro-

tating from 1 cycle to

another, the display

will show (- P), mean-

ing the position switch

is closed.
3

.

To advance valve,

press ¤ each time

you want to move

into next cycle.

(Pressing ¤ while

valve is rotating

has no affect.)

— Press and hold ¤ for 3 seconds to

move softener into fill cycle. Re-

move brinewell cover and, using a

flashlight, observe fill water enter-

ing tank.

continued

CAM

MOTOR

position

markers

PM

MO

WE TH FR SA

RCHG

.

.

AM

TU

SU

Advertising